{"title":"基于不同卧位的夜间动态心电图记录的分割","authors":"C. Maier, A. Benz, H. Dickhaus","doi":"10.1109/ESGCO.2014.6847568","DOIUrl":null,"url":null,"abstract":"This paper evaluates a previously developed approach for minute-by-minute segmentation of night-time ECG recordings with respect to periods of different recumbent body positions (BPs). It is based on recurrence analysis of 8D-feature vectors aggregating the area under the QRS complex in eight Holter-ECG leads. The number and consistency of ECG-derived BPs was compared to reference BPs (45° resolution) extracted from 139 polysomnograms (PSGs, 120 subjects). The results indicate a high BP resolution for the ECG. Up to 3 ECG BPs per PSG BP were identified in 70% of the cases. In 60% of the ECGs, the fraction of inconsistent epoch assignments was ≤10%, and ≤30% of BP changes in the PSG were undetected. When adjacent PSG BPs were considered exchangeable, the results improved significantly, indicating a potentially unfavorable effect of the PSG sensor discretization and encouraging further steps towards the absolute classification of BPs at least in coarse categories.","PeriodicalId":385389,"journal":{"name":"2014 8th Conference of the European Study Group on Cardiovascular Oscillations (ESGCO)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Segmentation of nocturnal Holter-ECG recordings with respect to different recumbent body positions\",\"authors\":\"C. Maier, A. Benz, H. Dickhaus\",\"doi\":\"10.1109/ESGCO.2014.6847568\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper evaluates a previously developed approach for minute-by-minute segmentation of night-time ECG recordings with respect to periods of different recumbent body positions (BPs). It is based on recurrence analysis of 8D-feature vectors aggregating the area under the QRS complex in eight Holter-ECG leads. The number and consistency of ECG-derived BPs was compared to reference BPs (45° resolution) extracted from 139 polysomnograms (PSGs, 120 subjects). The results indicate a high BP resolution for the ECG. Up to 3 ECG BPs per PSG BP were identified in 70% of the cases. In 60% of the ECGs, the fraction of inconsistent epoch assignments was ≤10%, and ≤30% of BP changes in the PSG were undetected. When adjacent PSG BPs were considered exchangeable, the results improved significantly, indicating a potentially unfavorable effect of the PSG sensor discretization and encouraging further steps towards the absolute classification of BPs at least in coarse categories.\",\"PeriodicalId\":385389,\"journal\":{\"name\":\"2014 8th Conference of the European Study Group on Cardiovascular Oscillations (ESGCO)\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 8th Conference of the European Study Group on Cardiovascular Oscillations (ESGCO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESGCO.2014.6847568\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 8th Conference of the European Study Group on Cardiovascular Oscillations (ESGCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESGCO.2014.6847568","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Segmentation of nocturnal Holter-ECG recordings with respect to different recumbent body positions
This paper evaluates a previously developed approach for minute-by-minute segmentation of night-time ECG recordings with respect to periods of different recumbent body positions (BPs). It is based on recurrence analysis of 8D-feature vectors aggregating the area under the QRS complex in eight Holter-ECG leads. The number and consistency of ECG-derived BPs was compared to reference BPs (45° resolution) extracted from 139 polysomnograms (PSGs, 120 subjects). The results indicate a high BP resolution for the ECG. Up to 3 ECG BPs per PSG BP were identified in 70% of the cases. In 60% of the ECGs, the fraction of inconsistent epoch assignments was ≤10%, and ≤30% of BP changes in the PSG were undetected. When adjacent PSG BPs were considered exchangeable, the results improved significantly, indicating a potentially unfavorable effect of the PSG sensor discretization and encouraging further steps towards the absolute classification of BPs at least in coarse categories.