近区域内不同手机的电场测量

S. Seker, G. Apaydin, C. Çelik
{"title":"近区域内不同手机的电场测量","authors":"S. Seker, G. Apaydin, C. Çelik","doi":"10.1109/ICSMC2.2003.1428278","DOIUrl":null,"url":null,"abstract":"In this work, electric field measurements are made in three categories. These are the near field measurements very close to the GSM phone for different phases (ringing, dialing, speaking) at the front, back, right and left sides of the phone, the electric field measurements at between 0-5 cm (1 cm intervals) away from the face and back of the GSM phone and the electric field measurements between 0-10 cm (1 cm intervals) away from the helix antenna which is fed by a 900MHz RF signal generator. These measurements were made by FP5000 isotropic probe that has frequency range between 10kHz-1GHz, dynamic range 1-300V/m. Fully charged mobile phone, which is under test, was fixed vertically on wooden platform and maximum electric field values were recorded. Only the position of probe was changed. During outgoing call phase, it's observed that the electric field at very close to mobile phone is much higher than limits specified by ICNIRP","PeriodicalId":272545,"journal":{"name":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Electric field measurements of different mobile handsets in near zone\",\"authors\":\"S. Seker, G. Apaydin, C. Çelik\",\"doi\":\"10.1109/ICSMC2.2003.1428278\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, electric field measurements are made in three categories. These are the near field measurements very close to the GSM phone for different phases (ringing, dialing, speaking) at the front, back, right and left sides of the phone, the electric field measurements at between 0-5 cm (1 cm intervals) away from the face and back of the GSM phone and the electric field measurements between 0-10 cm (1 cm intervals) away from the helix antenna which is fed by a 900MHz RF signal generator. These measurements were made by FP5000 isotropic probe that has frequency range between 10kHz-1GHz, dynamic range 1-300V/m. Fully charged mobile phone, which is under test, was fixed vertically on wooden platform and maximum electric field values were recorded. Only the position of probe was changed. During outgoing call phase, it's observed that the electric field at very close to mobile phone is much higher than limits specified by ICNIRP\",\"PeriodicalId\":272545,\"journal\":{\"name\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSMC2.2003.1428278\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSMC2.2003.1428278","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在这项工作中,电场测量分为三类。这些近场测量非常接近GSM电话的不同阶段(振铃,拨号,说话)在电话的前面,后面,右边和左边,电场测量0-5厘米(1厘米间隔)之间的GSM电话的脸和背面,电场测量0-10厘米(1厘米间隔)之间的螺旋天线,由900MHz射频信号发生器馈电。这些测量是由FP5000各向同性探头进行的,频率范围在10kHz-1GHz之间,动态范围为1-300V/m。将充满电的被测手机垂直固定在木制平台上,记录最大电场值。只是改变了探针的位置。在呼出阶段,观察到手机附近的电场远高于ICNIRP规定的限值
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electric field measurements of different mobile handsets in near zone
In this work, electric field measurements are made in three categories. These are the near field measurements very close to the GSM phone for different phases (ringing, dialing, speaking) at the front, back, right and left sides of the phone, the electric field measurements at between 0-5 cm (1 cm intervals) away from the face and back of the GSM phone and the electric field measurements between 0-10 cm (1 cm intervals) away from the helix antenna which is fed by a 900MHz RF signal generator. These measurements were made by FP5000 isotropic probe that has frequency range between 10kHz-1GHz, dynamic range 1-300V/m. Fully charged mobile phone, which is under test, was fixed vertically on wooden platform and maximum electric field values were recorded. Only the position of probe was changed. During outgoing call phase, it's observed that the electric field at very close to mobile phone is much higher than limits specified by ICNIRP
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信