文物立面的风吹雨打和湿气损坏风险

A. Kubilay, J. Bourcet, Jessica Gravel, Xiaohai Zhou, D. Derome, J. Carmeliet
{"title":"文物立面的风吹雨打和湿气损坏风险","authors":"A. Kubilay, J. Bourcet, Jessica Gravel, Xiaohai Zhou, D. Derome, J. Carmeliet","doi":"10.14293/ICMB210034","DOIUrl":null,"url":null,"abstract":"Accurate estimation of wind-driven rain (WDR) load on building facades is of paramount importance for the assessment of moisture-induced damage risks. Computational fluid dynamics (CFD) simulations of WDR are performed for the Parliament Buildings in Ottawa, Canada. Combined with a statistical analysis of the long-term local meteorological conditions, zones of facades receiving the highest amount of WDR are determined. Then, for critical locations on the facade, the Climatic Index is used as a metric, taking into account the total wetting load and total drying potential, in order to identify the façade locations and periods that show high risk of moisture damage.","PeriodicalId":196752,"journal":{"name":"Wind-driven rain exposure and moisture damage risk of heritage facades","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Wind-driven rain exposure and moisture damage risk of heritage facades\",\"authors\":\"A. Kubilay, J. Bourcet, Jessica Gravel, Xiaohai Zhou, D. Derome, J. Carmeliet\",\"doi\":\"10.14293/ICMB210034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate estimation of wind-driven rain (WDR) load on building facades is of paramount importance for the assessment of moisture-induced damage risks. Computational fluid dynamics (CFD) simulations of WDR are performed for the Parliament Buildings in Ottawa, Canada. Combined with a statistical analysis of the long-term local meteorological conditions, zones of facades receiving the highest amount of WDR are determined. Then, for critical locations on the facade, the Climatic Index is used as a metric, taking into account the total wetting load and total drying potential, in order to identify the façade locations and periods that show high risk of moisture damage.\",\"PeriodicalId\":196752,\"journal\":{\"name\":\"Wind-driven rain exposure and moisture damage risk of heritage facades\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wind-driven rain exposure and moisture damage risk of heritage facades\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14293/ICMB210034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wind-driven rain exposure and moisture damage risk of heritage facades","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14293/ICMB210034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

准确估算建筑外立面的风雨荷载对于湿气损伤风险评估至关重要。以加拿大渥太华的国会大厦为研究对象,进行了WDR的计算流体动力学(CFD)模拟。结合对当地长期气象条件的统计分析,确定了接收最高WDR量的立面区域。然后,对于立面上的关键位置,考虑到总湿负荷和总干燥潜力,使用气候指数作为度量标准,以确定立面位置和时间,显示出水分破坏的高风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wind-driven rain exposure and moisture damage risk of heritage facades
Accurate estimation of wind-driven rain (WDR) load on building facades is of paramount importance for the assessment of moisture-induced damage risks. Computational fluid dynamics (CFD) simulations of WDR are performed for the Parliament Buildings in Ottawa, Canada. Combined with a statistical analysis of the long-term local meteorological conditions, zones of facades receiving the highest amount of WDR are determined. Then, for critical locations on the facade, the Climatic Index is used as a metric, taking into account the total wetting load and total drying potential, in order to identify the façade locations and periods that show high risk of moisture damage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信