D M Glover, P K Hopke, S J Vermette, S Landsberger, D R D'Auben
{"title":"具有站点特定源配置文件的源分配。","authors":"D M Glover, P K Hopke, S J Vermette, S Landsberger, D R D'Auben","doi":"10.1080/10473289.1991.10466846","DOIUrl":null,"url":null,"abstract":"<p><p>A receptor modeling study was performed to identify and apportion the sources of PM10 mass in Granite City, Illinois, an area of historic TSP nonattainment. Samples of the ambient aerosol were collected using a dichotomous sampler. Each sample was analyzed by x-ray fluorescence and instrumental neutron activation analysis. To begin the study, a factor analysis was performed. Two different chemical mass balance (CMB) analyses were then made. The first CMB analysis used only source profiles available from the literature while the second included twelve source profiles developed from dust samples collected in Granite City. Both CMB analyses used 20 of the 33 analyzed elements since many of the source profiles in the literature did not include the other thirteen elements. The results from both sets of CMB analyses were grouped by the predominate wind direction at the site during the time each sample was taken to identify the direction of each source relative to the sampler. It was found that regional sources were the primary contributors to the fine fraction while the coarse fraction was composed of material from local industries. These sources were generally the ones identified during the Regional Air Pollution Study previously conducted in the area. However, the emission profiles from these sources were observed to have changed between the studies. It was also found that the use of the locally generated profiles greatly improved the results of the CMB analysis.</p>","PeriodicalId":17202,"journal":{"name":"Journal of the Air & Waste Management Association","volume":"41 3","pages":"294-305"},"PeriodicalIF":2.7000,"publicationDate":"1991-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/10473289.1991.10466846","citationCount":"25","resultStr":"{\"title\":\"Source apportionment with site specific source profiles.\",\"authors\":\"D M Glover, P K Hopke, S J Vermette, S Landsberger, D R D'Auben\",\"doi\":\"10.1080/10473289.1991.10466846\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A receptor modeling study was performed to identify and apportion the sources of PM10 mass in Granite City, Illinois, an area of historic TSP nonattainment. Samples of the ambient aerosol were collected using a dichotomous sampler. Each sample was analyzed by x-ray fluorescence and instrumental neutron activation analysis. To begin the study, a factor analysis was performed. Two different chemical mass balance (CMB) analyses were then made. The first CMB analysis used only source profiles available from the literature while the second included twelve source profiles developed from dust samples collected in Granite City. Both CMB analyses used 20 of the 33 analyzed elements since many of the source profiles in the literature did not include the other thirteen elements. The results from both sets of CMB analyses were grouped by the predominate wind direction at the site during the time each sample was taken to identify the direction of each source relative to the sampler. It was found that regional sources were the primary contributors to the fine fraction while the coarse fraction was composed of material from local industries. These sources were generally the ones identified during the Regional Air Pollution Study previously conducted in the area. However, the emission profiles from these sources were observed to have changed between the studies. It was also found that the use of the locally generated profiles greatly improved the results of the CMB analysis.</p>\",\"PeriodicalId\":17202,\"journal\":{\"name\":\"Journal of the Air & Waste Management Association\",\"volume\":\"41 3\",\"pages\":\"294-305\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"1991-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/10473289.1991.10466846\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Air & Waste Management Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/10473289.1991.10466846\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Air & Waste Management Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/10473289.1991.10466846","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Source apportionment with site specific source profiles.
A receptor modeling study was performed to identify and apportion the sources of PM10 mass in Granite City, Illinois, an area of historic TSP nonattainment. Samples of the ambient aerosol were collected using a dichotomous sampler. Each sample was analyzed by x-ray fluorescence and instrumental neutron activation analysis. To begin the study, a factor analysis was performed. Two different chemical mass balance (CMB) analyses were then made. The first CMB analysis used only source profiles available from the literature while the second included twelve source profiles developed from dust samples collected in Granite City. Both CMB analyses used 20 of the 33 analyzed elements since many of the source profiles in the literature did not include the other thirteen elements. The results from both sets of CMB analyses were grouped by the predominate wind direction at the site during the time each sample was taken to identify the direction of each source relative to the sampler. It was found that regional sources were the primary contributors to the fine fraction while the coarse fraction was composed of material from local industries. These sources were generally the ones identified during the Regional Air Pollution Study previously conducted in the area. However, the emission profiles from these sources were observed to have changed between the studies. It was also found that the use of the locally generated profiles greatly improved the results of the CMB analysis.
期刊介绍:
The Journal of the Air & Waste Management Association (J&AWMA) is one of the oldest continuously published, peer-reviewed, technical environmental journals in the world. First published in 1951 under the name Air Repair, J&AWMA is intended to serve those occupationally involved in air pollution control and waste management through the publication of timely and reliable information.