柔性电缆对电弧炉炼钢厂谐波产生的影响

H. Khoshkhoo, S. Sadeghi, R. Moini, M. Jabbari
{"title":"柔性电缆对电弧炉炼钢厂谐波产生的影响","authors":"H. Khoshkhoo, S. Sadeghi, R. Moini, M. Jabbari","doi":"10.1109/INMIC.2008.4777699","DOIUrl":null,"url":null,"abstract":"A three-phase dynamic arc furnace model is presented to investigate the effect of flexible power cables oscillations on harmonic generation of an arc-furnace steel plant. In this model, the flexible cables are presented by a varying three-phase inductor bank connected in series to the arc furnace. The self and mutual inductances of the inductors are calculated at each time step, using the shape of the cables. The shape of each cable is, in turn, obtained using the arc-furnace current computed in the preceding time step. The simulation results show that the inclusion of the flexible power cables in the arc furnace model does not have a significant effect on the magnitudes of the plant generated harmonics. However, the cables oscillations can remarkably affect the level of unbalancy in the three-phase system.","PeriodicalId":112530,"journal":{"name":"2008 IEEE International Multitopic Conference","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of flexible power cables on harmonic generation of an arc furnace steel plant\",\"authors\":\"H. Khoshkhoo, S. Sadeghi, R. Moini, M. Jabbari\",\"doi\":\"10.1109/INMIC.2008.4777699\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A three-phase dynamic arc furnace model is presented to investigate the effect of flexible power cables oscillations on harmonic generation of an arc-furnace steel plant. In this model, the flexible cables are presented by a varying three-phase inductor bank connected in series to the arc furnace. The self and mutual inductances of the inductors are calculated at each time step, using the shape of the cables. The shape of each cable is, in turn, obtained using the arc-furnace current computed in the preceding time step. The simulation results show that the inclusion of the flexible power cables in the arc furnace model does not have a significant effect on the magnitudes of the plant generated harmonics. However, the cables oscillations can remarkably affect the level of unbalancy in the three-phase system.\",\"PeriodicalId\":112530,\"journal\":{\"name\":\"2008 IEEE International Multitopic Conference\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 IEEE International Multitopic Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INMIC.2008.4777699\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE International Multitopic Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INMIC.2008.4777699","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

建立了电弧炉三相动态模型,研究了柔性电缆振荡对电弧炉炼钢厂谐波产生的影响。在该模型中,柔性电缆由串联连接到电弧炉的可变三相电感组来表示。利用电缆的形状,在每个时间步长计算电感器的自感和互感。每根电缆的形状依次由前一时间步计算的电弧炉电流得到。仿真结果表明,在电弧炉模型中加入柔性电力电缆对工厂产生的谐波大小没有显著影响。然而,电缆的振荡会显著影响三相系统的不平衡程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of flexible power cables on harmonic generation of an arc furnace steel plant
A three-phase dynamic arc furnace model is presented to investigate the effect of flexible power cables oscillations on harmonic generation of an arc-furnace steel plant. In this model, the flexible cables are presented by a varying three-phase inductor bank connected in series to the arc furnace. The self and mutual inductances of the inductors are calculated at each time step, using the shape of the cables. The shape of each cable is, in turn, obtained using the arc-furnace current computed in the preceding time step. The simulation results show that the inclusion of the flexible power cables in the arc furnace model does not have a significant effect on the magnitudes of the plant generated harmonics. However, the cables oscillations can remarkably affect the level of unbalancy in the three-phase system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信