交叉相位极化算法确定故障方向,采用过零法确定相位差

A. A. Z. Zainul Abidin, A. Ramasamy, I. Abidin, F. Nagi
{"title":"交叉相位极化算法确定故障方向,采用过零法确定相位差","authors":"A. A. Z. Zainul Abidin, A. Ramasamy, I. Abidin, F. Nagi","doi":"10.1109/ICEENVIRON.2009.5398619","DOIUrl":null,"url":null,"abstract":"Power systems are usually connected in a condition where there is more than one power supply or voltage source supplying a load. These systems will have protection relays to protect various equipment connected to the system. However in isolating a fault, the direction of the fault needs to be known in order to limit the amount of loss load. This paper shall describe a possible algorithm that could be used in order to perform cross phase polarization. The possible faults that could be detected using this technique include the single phase to ground fault, the phase to phase fault and the double phase to ground fault. Three phase faults require the memory polarization technique that will not be discussed in this paper. The algorithm shall be implemented and tested using the sim power system tool box present in MATLAB.","PeriodicalId":211736,"journal":{"name":"2009 3rd International Conference on Energy and Environment (ICEE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference\",\"authors\":\"A. A. Z. Zainul Abidin, A. Ramasamy, I. Abidin, F. Nagi\",\"doi\":\"10.1109/ICEENVIRON.2009.5398619\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power systems are usually connected in a condition where there is more than one power supply or voltage source supplying a load. These systems will have protection relays to protect various equipment connected to the system. However in isolating a fault, the direction of the fault needs to be known in order to limit the amount of loss load. This paper shall describe a possible algorithm that could be used in order to perform cross phase polarization. The possible faults that could be detected using this technique include the single phase to ground fault, the phase to phase fault and the double phase to ground fault. Three phase faults require the memory polarization technique that will not be discussed in this paper. The algorithm shall be implemented and tested using the sim power system tool box present in MATLAB.\",\"PeriodicalId\":211736,\"journal\":{\"name\":\"2009 3rd International Conference on Energy and Environment (ICEE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 3rd International Conference on Energy and Environment (ICEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEENVIRON.2009.5398619\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 3rd International Conference on Energy and Environment (ICEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEENVIRON.2009.5398619","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电力系统通常连接在有多个电源或电压源为负载供电的情况下。这些系统将有保护继电器来保护连接到系统的各种设备。然而,在隔离故障时,需要知道故障的方向,以限制损失负载的数量。本文将描述一种可能的算法,可以用来执行交叉相位极化。该技术可检测的故障包括单相接地故障、相接地故障和双相接地故障。三相故障需要使用记忆极化技术,本文不作讨论。该算法需要使用MATLAB中提供的sim电源系统工具箱来实现和测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cross phase polarization algorithm for fault direction determination using zero crossing method to determine phase difference
Power systems are usually connected in a condition where there is more than one power supply or voltage source supplying a load. These systems will have protection relays to protect various equipment connected to the system. However in isolating a fault, the direction of the fault needs to be known in order to limit the amount of loss load. This paper shall describe a possible algorithm that could be used in order to perform cross phase polarization. The possible faults that could be detected using this technique include the single phase to ground fault, the phase to phase fault and the double phase to ground fault. Three phase faults require the memory polarization technique that will not be discussed in this paper. The algorithm shall be implemented and tested using the sim power system tool box present in MATLAB.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信