通过适当的热泵开关,降低热水制备能耗的可能性

Jan Rimbala, J. Kynčl
{"title":"通过适当的热泵开关,降低热水制备能耗的可能性","authors":"Jan Rimbala, J. Kynčl","doi":"10.1109/EPE51172.2020.9269251","DOIUrl":null,"url":null,"abstract":"The article deals with the possibilities of reducing energy consumption for the preparation of hot water by suitable switching of the air-to-water heat pump according to the expected time course of the outdoor air temperature. Higher temperature of the medium from which we pump heat always leads to an improvement of the heating factor. The article describes an idealized model taking into account two water storage The consumed electrical energy is always evaluated at the worst possible switching time of the heat pump, at a fixed switching time and with optimal switching. The considered procedure may be suitable for buildings with high hot water consumption, such as hospitals, retirement homes, or for small industrial enterprises.","PeriodicalId":177031,"journal":{"name":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The possibilities of reducing energy consumption for the preparation of hot water by suitable switching of the heat pump\",\"authors\":\"Jan Rimbala, J. Kynčl\",\"doi\":\"10.1109/EPE51172.2020.9269251\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article deals with the possibilities of reducing energy consumption for the preparation of hot water by suitable switching of the air-to-water heat pump according to the expected time course of the outdoor air temperature. Higher temperature of the medium from which we pump heat always leads to an improvement of the heating factor. The article describes an idealized model taking into account two water storage The consumed electrical energy is always evaluated at the worst possible switching time of the heat pump, at a fixed switching time and with optimal switching. The considered procedure may be suitable for buildings with high hot water consumption, such as hospitals, retirement homes, or for small industrial enterprises.\",\"PeriodicalId\":177031,\"journal\":{\"name\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE51172.2020.9269251\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE51172.2020.9269251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文论述了根据室外空气温度的预期时间过程,通过对空气-水热泵进行适当的开关,降低热水制备能耗的可能性。我们从中抽取热量的介质温度越高,加热系数就越高。本文描述了一个考虑两种蓄水量的理想模型,该模型总是在热泵最坏的可能开关时间、固定开关时间和最佳开关情况下评估所消耗的电能。所考虑的程序可能适用于热水消耗量大的建筑物,如医院、养老院或小型工业企业。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The possibilities of reducing energy consumption for the preparation of hot water by suitable switching of the heat pump
The article deals with the possibilities of reducing energy consumption for the preparation of hot water by suitable switching of the air-to-water heat pump according to the expected time course of the outdoor air temperature. Higher temperature of the medium from which we pump heat always leads to an improvement of the heating factor. The article describes an idealized model taking into account two water storage The consumed electrical energy is always evaluated at the worst possible switching time of the heat pump, at a fixed switching time and with optimal switching. The considered procedure may be suitable for buildings with high hot water consumption, such as hospitals, retirement homes, or for small industrial enterprises.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信