碳纳米管膜作为伏安电子舌系统的对电极

Yazhuo Li, Xiangdong Zhou
{"title":"碳纳米管膜作为伏安电子舌系统的对电极","authors":"Yazhuo Li, Xiangdong Zhou","doi":"10.1117/12.2511144","DOIUrl":null,"url":null,"abstract":"Carbon nanotube membrane (CNTM) has been employed as the counter electrode in a two-electrode voltammetric electronic tongue system. Owing to its large surface area, CNTM provides significant double layer capacitance at the solid/solution interface, and offer a constant potential during the electrochemical detection. In order to characterize the analytical possibilities of the electronic tongue system, hydrogen peroxide has been detected. Principal component analysis (PCA) is used for identification. From the PCA plots, the electronic tongue system by using CNTM counter electrode shows much better performance and more promising than the conventional voltammetric two-electrode electronic tongue system by using large surface stainless steel counter electrode.","PeriodicalId":115119,"journal":{"name":"International Symposium on Precision Engineering Measurement and Instrumentation","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Using carbon nanotube membrane as counter electrode in voltammetric electronic tongue system\",\"authors\":\"Yazhuo Li, Xiangdong Zhou\",\"doi\":\"10.1117/12.2511144\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Carbon nanotube membrane (CNTM) has been employed as the counter electrode in a two-electrode voltammetric electronic tongue system. Owing to its large surface area, CNTM provides significant double layer capacitance at the solid/solution interface, and offer a constant potential during the electrochemical detection. In order to characterize the analytical possibilities of the electronic tongue system, hydrogen peroxide has been detected. Principal component analysis (PCA) is used for identification. From the PCA plots, the electronic tongue system by using CNTM counter electrode shows much better performance and more promising than the conventional voltammetric two-electrode electronic tongue system by using large surface stainless steel counter electrode.\",\"PeriodicalId\":115119,\"journal\":{\"name\":\"International Symposium on Precision Engineering Measurement and Instrumentation\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Symposium on Precision Engineering Measurement and Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2511144\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Precision Engineering Measurement and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2511144","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用碳纳米管膜(CNTM)作为双电极伏安电子舌系统的对电极。由于其较大的表面积,CNTM在固/液界面提供显著的双层电容,并在电化学检测过程中提供恒定的电位。为了表征电子舌系统的分析可能性,检测了过氧化氢。使用主成分分析(PCA)进行识别。从主成分分析图来看,采用CNTM对电极的电子舌系统比采用大表面不锈钢对电极的传统伏安双电极电子舌系统表现出更好的性能和前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Using carbon nanotube membrane as counter electrode in voltammetric electronic tongue system
Carbon nanotube membrane (CNTM) has been employed as the counter electrode in a two-electrode voltammetric electronic tongue system. Owing to its large surface area, CNTM provides significant double layer capacitance at the solid/solution interface, and offer a constant potential during the electrochemical detection. In order to characterize the analytical possibilities of the electronic tongue system, hydrogen peroxide has been detected. Principal component analysis (PCA) is used for identification. From the PCA plots, the electronic tongue system by using CNTM counter electrode shows much better performance and more promising than the conventional voltammetric two-electrode electronic tongue system by using large surface stainless steel counter electrode.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信