B. Alemayehu, Akash Kota, Amy T. Neidhard-Doll, V. Chodavarapu, G. Subramanyam
{"title":"使用单芯片阻抗分析仪监测公用事业变压器的运行状况","authors":"B. Alemayehu, Akash Kota, Amy T. Neidhard-Doll, V. Chodavarapu, G. Subramanyam","doi":"10.1109/NAECON46414.2019.9058239","DOIUrl":null,"url":null,"abstract":"Dissolved gas analysis and oil sample analysis have been established as effective ways of determining the transformer oil health. In this paper, we present a new approach to diagnose the oil condition towards utility transformer health monitoring based on using the AD5933 single chip impedance analyzer from Analog Devices. We propose an integrated smart infrastructure monitoring with the results from the impedance analyzer transmitted, logged, and processed via a cloud computing interface. The transformer oils are characterized and monitored by analyzing their impedance values over a range of frequencies from 1 kHz to 100 kHz.","PeriodicalId":193529,"journal":{"name":"2019 IEEE National Aerospace and Electronics Conference (NAECON)","volume":"156 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Utility Transformer Health Monitoring using a Single Chip Impedance Analyzer\",\"authors\":\"B. Alemayehu, Akash Kota, Amy T. Neidhard-Doll, V. Chodavarapu, G. Subramanyam\",\"doi\":\"10.1109/NAECON46414.2019.9058239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Dissolved gas analysis and oil sample analysis have been established as effective ways of determining the transformer oil health. In this paper, we present a new approach to diagnose the oil condition towards utility transformer health monitoring based on using the AD5933 single chip impedance analyzer from Analog Devices. We propose an integrated smart infrastructure monitoring with the results from the impedance analyzer transmitted, logged, and processed via a cloud computing interface. The transformer oils are characterized and monitored by analyzing their impedance values over a range of frequencies from 1 kHz to 100 kHz.\",\"PeriodicalId\":193529,\"journal\":{\"name\":\"2019 IEEE National Aerospace and Electronics Conference (NAECON)\",\"volume\":\"156 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE National Aerospace and Electronics Conference (NAECON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAECON46414.2019.9058239\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE National Aerospace and Electronics Conference (NAECON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAECON46414.2019.9058239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

溶解气体分析和油样分析是确定变压器油健康状况的有效方法。本文提出了一种基于adi公司AD5933单片机阻抗分析仪的变压器油况诊断方法。我们提出了一种集成的智能基础设施监测,通过云计算接口传输、记录和处理阻抗分析仪的结果。通过分析变压器油在1 kHz至100 kHz频率范围内的阻抗值来表征和监测变压器油。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Utility Transformer Health Monitoring using a Single Chip Impedance Analyzer
Dissolved gas analysis and oil sample analysis have been established as effective ways of determining the transformer oil health. In this paper, we present a new approach to diagnose the oil condition towards utility transformer health monitoring based on using the AD5933 single chip impedance analyzer from Analog Devices. We propose an integrated smart infrastructure monitoring with the results from the impedance analyzer transmitted, logged, and processed via a cloud computing interface. The transformer oils are characterized and monitored by analyzing their impedance values over a range of frequencies from 1 kHz to 100 kHz.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信