行走分析用六轴力传感器的制造与校核

K. Sekiguchi, M. Ueda, H. Takemura, H. Mizoguchi
{"title":"行走分析用六轴力传感器的制造与校核","authors":"K. Sekiguchi, M. Ueda, H. Takemura, H. Mizoguchi","doi":"10.1109/SICE.2008.4655114","DOIUrl":null,"url":null,"abstract":"In this research, it has aimed at the development of the walking analysis device that takes the influence that the sense machine gives into consideration. The production of six axis power sensor that is the floor reaction force meter to which the use simultaneously with the acquisition of the image of the skin transformation of the back of the foot is required and the evaluation method are described for that.","PeriodicalId":152347,"journal":{"name":"2008 SICE Annual Conference","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Manufacture and proofreading of 6-axis force sensor for walking analysis\",\"authors\":\"K. Sekiguchi, M. Ueda, H. Takemura, H. Mizoguchi\",\"doi\":\"10.1109/SICE.2008.4655114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this research, it has aimed at the development of the walking analysis device that takes the influence that the sense machine gives into consideration. The production of six axis power sensor that is the floor reaction force meter to which the use simultaneously with the acquisition of the image of the skin transformation of the back of the foot is required and the evaluation method are described for that.\",\"PeriodicalId\":152347,\"journal\":{\"name\":\"2008 SICE Annual Conference\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 SICE Annual Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SICE.2008.4655114\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 SICE Annual Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2008.4655114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在本研究中,旨在开发考虑到感知机影响的步行分析装置。要求制作与采集足后皮肤变化图像同时使用的六轴力传感器即地板反力计,并描述了其评价方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Manufacture and proofreading of 6-axis force sensor for walking analysis
In this research, it has aimed at the development of the walking analysis device that takes the influence that the sense machine gives into consideration. The production of six axis power sensor that is the floor reaction force meter to which the use simultaneously with the acquisition of the image of the skin transformation of the back of the foot is required and the evaluation method are described for that.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信