跟腱和髋端T2*定位的实验装置

P. Latta, V. Juras, M. Kojan, Z. Starčuk, X. Deligianni, O. Bieri, P. Szomolanyi, I. Frollo, S. Trattnig
{"title":"跟腱和髋端T2*定位的实验装置","authors":"P. Latta, V. Juras, M. Kojan, Z. Starčuk, X. Deligianni, O. Bieri, P. Szomolanyi, I. Frollo, S. Trattnig","doi":"10.23919/MEASUREMENT47340.2019.8779934","DOIUrl":null,"url":null,"abstract":"The experimental setup for accurate T2 * mapping of Achilles tendon and enthesis was developed. The setup consists of a specially designed MR compatible RF coil holder and custom-made ultrashort echo time (UTE) pulse sequence. The performance of the UTE sequence was tested and compared with data obtained by variable echo time (vTE) sequence. The results showed that T2* values calculated with vTE are overestimated in comparison to UTE, however, the clinical adaptation of vTE might be easier, since it provides more slices with reduced blurring and lower scan times.","PeriodicalId":129350,"journal":{"name":"2019 12th International Conference on Measurement","volume":"641 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Experimental Setup for T2* Mapping in Achilles tendon and Enthesis\",\"authors\":\"P. Latta, V. Juras, M. Kojan, Z. Starčuk, X. Deligianni, O. Bieri, P. Szomolanyi, I. Frollo, S. Trattnig\",\"doi\":\"10.23919/MEASUREMENT47340.2019.8779934\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The experimental setup for accurate T2 * mapping of Achilles tendon and enthesis was developed. The setup consists of a specially designed MR compatible RF coil holder and custom-made ultrashort echo time (UTE) pulse sequence. The performance of the UTE sequence was tested and compared with data obtained by variable echo time (vTE) sequence. The results showed that T2* values calculated with vTE are overestimated in comparison to UTE, however, the clinical adaptation of vTE might be easier, since it provides more slices with reduced blurring and lower scan times.\",\"PeriodicalId\":129350,\"journal\":{\"name\":\"2019 12th International Conference on Measurement\",\"volume\":\"641 \",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 12th International Conference on Measurement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/MEASUREMENT47340.2019.8779934\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 12th International Conference on Measurement","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/MEASUREMENT47340.2019.8779934","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

建立了跟腱和椎体精确T2 *定位的实验装置。该装置由一个专门设计的MR兼容射频线圈支架和定制的超短回波时间(UTE)脉冲序列组成。对UTE序列的性能进行了测试,并与变回波时间序列(vTE)获得的数据进行了比较。结果显示,与UTE相比,vTE计算的T2*值被高估,但vTE的临床适应可能更容易,因为它提供了更多的切片,减少了模糊,减少了扫描时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Experimental Setup for T2* Mapping in Achilles tendon and Enthesis
The experimental setup for accurate T2 * mapping of Achilles tendon and enthesis was developed. The setup consists of a specially designed MR compatible RF coil holder and custom-made ultrashort echo time (UTE) pulse sequence. The performance of the UTE sequence was tested and compared with data obtained by variable echo time (vTE) sequence. The results showed that T2* values calculated with vTE are overestimated in comparison to UTE, however, the clinical adaptation of vTE might be easier, since it provides more slices with reduced blurring and lower scan times.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信