电梯坑积水分级报警装置的设计

Zhang Yanbin, Feng Shuangchang, Chen Jie, Li Zheyi
{"title":"电梯坑积水分级报警装置的设计","authors":"Zhang Yanbin, Feng Shuangchang, Chen Jie, Li Zheyi","doi":"10.1109/ICSP51882.2021.9409005","DOIUrl":null,"url":null,"abstract":"With the continuous development of urbanization in modern society, the number of elevators is increasing. In the process of building construction in the city, because part of the building bottom waterproof measures are not in place, every rain season, the elevator pit water seepage phenomenon. Excessive water will lead to the failure of related electrical safety devices and the service life of related components. This thesis describes the device mainly include the CPU, the elevator controller, pump, alarm monitoring center, and respectively set on the bottom of the elevator guide rail on the right Angle bracket of pit and highly first water level sensor, which may vary from the second water level sensor and the third water level sensor, which can effectively monitor the elevator pit water level change and start the emergency measures, minimizes the negative effects of product.","PeriodicalId":117159,"journal":{"name":"2021 6th International Conference on Intelligent Computing and Signal Processing (ICSP)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of a classification warning device for the accumulation of water in the elevator pit\",\"authors\":\"Zhang Yanbin, Feng Shuangchang, Chen Jie, Li Zheyi\",\"doi\":\"10.1109/ICSP51882.2021.9409005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the continuous development of urbanization in modern society, the number of elevators is increasing. In the process of building construction in the city, because part of the building bottom waterproof measures are not in place, every rain season, the elevator pit water seepage phenomenon. Excessive water will lead to the failure of related electrical safety devices and the service life of related components. This thesis describes the device mainly include the CPU, the elevator controller, pump, alarm monitoring center, and respectively set on the bottom of the elevator guide rail on the right Angle bracket of pit and highly first water level sensor, which may vary from the second water level sensor and the third water level sensor, which can effectively monitor the elevator pit water level change and start the emergency measures, minimizes the negative effects of product.\",\"PeriodicalId\":117159,\"journal\":{\"name\":\"2021 6th International Conference on Intelligent Computing and Signal Processing (ICSP)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 6th International Conference on Intelligent Computing and Signal Processing (ICSP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSP51882.2021.9409005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 6th International Conference on Intelligent Computing and Signal Processing (ICSP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSP51882.2021.9409005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着现代社会城市化的不断发展,电梯的数量越来越多。在城市建筑施工过程中,由于部分建筑底部防水措施不到位,每到雨季,电梯坑就会出现渗水现象。进水过多会导致相关电气安全装置失效,影响相关部件的使用寿命。本论文所描述的设备主要包括CPU、电梯控制器、水泵、报警监控中心,并分别设置在电梯导轨底部的直角支架上的深坑和高度处的第一水位传感器,其中可能有异于第二水位传感器和第三水位传感器,它可以有效地监测电梯深坑水位的变化并启动应急措施,最大限度地减少产品的负面影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of a classification warning device for the accumulation of water in the elevator pit
With the continuous development of urbanization in modern society, the number of elevators is increasing. In the process of building construction in the city, because part of the building bottom waterproof measures are not in place, every rain season, the elevator pit water seepage phenomenon. Excessive water will lead to the failure of related electrical safety devices and the service life of related components. This thesis describes the device mainly include the CPU, the elevator controller, pump, alarm monitoring center, and respectively set on the bottom of the elevator guide rail on the right Angle bracket of pit and highly first water level sensor, which may vary from the second water level sensor and the third water level sensor, which can effectively monitor the elevator pit water level change and start the emergency measures, minimizes the negative effects of product.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信