{"title":"基于低侧开关集成电流传感器的三相逆变器电流重构算法","authors":"S. Chakrabarti, T. Jahns, R. Lorenz","doi":"10.1109/IAS.2003.1257646","DOIUrl":null,"url":null,"abstract":"Power semiconductor switches that include integrated pilot current sensors create opportunities to eliminate external current sensors in three-phase inverter applications. Each of the three conventional low-side power switches in a three-phase inverter can be replaced by one of these special devices that is designed to provide a sensing level current that accurately mirrors its total forward current. Recognizing that the output current in each phase flows through the low-side switch for only a portion of the fundamental cycle, a technique has been developed to reconstruct the full phase current waveforms for R-L loads using only the incomplete phase current measurements. The performance characteristics of the proposed current reconstruction technique are experimentally verified, including demonstration of a closed-loop three-phase current regulator using the reconstructed current feedback from the integrated pilot current sensors.","PeriodicalId":288109,"journal":{"name":"38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003.","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"33","resultStr":"{\"title\":\"A current reconstruction algorithm for three-phase inverters using integrated current sensors in the low-side switches\",\"authors\":\"S. Chakrabarti, T. Jahns, R. Lorenz\",\"doi\":\"10.1109/IAS.2003.1257646\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power semiconductor switches that include integrated pilot current sensors create opportunities to eliminate external current sensors in three-phase inverter applications. Each of the three conventional low-side power switches in a three-phase inverter can be replaced by one of these special devices that is designed to provide a sensing level current that accurately mirrors its total forward current. Recognizing that the output current in each phase flows through the low-side switch for only a portion of the fundamental cycle, a technique has been developed to reconstruct the full phase current waveforms for R-L loads using only the incomplete phase current measurements. The performance characteristics of the proposed current reconstruction technique are experimentally verified, including demonstration of a closed-loop three-phase current regulator using the reconstructed current feedback from the integrated pilot current sensors.\",\"PeriodicalId\":288109,\"journal\":{\"name\":\"38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003.\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"33\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2003.1257646\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2003.1257646","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A current reconstruction algorithm for three-phase inverters using integrated current sensors in the low-side switches
Power semiconductor switches that include integrated pilot current sensors create opportunities to eliminate external current sensors in three-phase inverter applications. Each of the three conventional low-side power switches in a three-phase inverter can be replaced by one of these special devices that is designed to provide a sensing level current that accurately mirrors its total forward current. Recognizing that the output current in each phase flows through the low-side switch for only a portion of the fundamental cycle, a technique has been developed to reconstruct the full phase current waveforms for R-L loads using only the incomplete phase current measurements. The performance characteristics of the proposed current reconstruction technique are experimentally verified, including demonstration of a closed-loop three-phase current regulator using the reconstructed current feedback from the integrated pilot current sensors.