Thị Như Ý Lê, Minh Sơn Lê, Ngọc Trí Huỳnh Nguyễn, Khánh Sơn Nguyễn
{"title":"流式流量计的实验,跟踪粘度参数的变化,高质量混凝土的流动阈值。","authors":"Thị Như Ý Lê, Minh Sơn Lê, Ngọc Trí Huỳnh Nguyễn, Khánh Sơn Nguyễn","doi":"10.59382/j-ibst.2022.vi.vol4-6","DOIUrl":null,"url":null,"abstract":"In this paper, authors present the experimental studies of rheological properties of high performance concrete. In general, rheological properties including viscosity and yeild stress report the workability of concrete material after mixing step. Authors used a coaxial with vane type rheometer in laboratory to measure the rotational moment of the prepared HPC material. Obtained results showed the compressive strength of such HPC around 120 MPa after 28 days of curing period. Measured vicosity and yeild stress increases over time in the period of 0-100 minutes. 70 minutes after mixing, the studied mixture of HPC lost the workability considering the large variation of both vicosity and yeild stress values.","PeriodicalId":350876,"journal":{"name":"Vietnam Institute for Building Science and Technology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"THỰC NGHIỆM DÙNG LƯU BIẾN KẾ THEO DÕI SỰ BIẾN THIÊN CÁC THÔNG \\nSỐ ĐỘ NHỚT, NGƯỠNG CHẢY CỦA VỮA BÊ-TÔNG TÍNH NĂNG CAO\",\"authors\":\"Thị Như Ý Lê, Minh Sơn Lê, Ngọc Trí Huỳnh Nguyễn, Khánh Sơn Nguyễn\",\"doi\":\"10.59382/j-ibst.2022.vi.vol4-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, authors present the experimental studies of rheological properties of high performance concrete. In general, rheological properties including viscosity and yeild stress report the workability of concrete material after mixing step. Authors used a coaxial with vane type rheometer in laboratory to measure the rotational moment of the prepared HPC material. Obtained results showed the compressive strength of such HPC around 120 MPa after 28 days of curing period. Measured vicosity and yeild stress increases over time in the period of 0-100 minutes. 70 minutes after mixing, the studied mixture of HPC lost the workability considering the large variation of both vicosity and yeild stress values.\",\"PeriodicalId\":350876,\"journal\":{\"name\":\"Vietnam Institute for Building Science and Technology\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vietnam Institute for Building Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.59382/j-ibst.2022.vi.vol4-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vietnam Institute for Building Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.59382/j-ibst.2022.vi.vol4-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
THỰC NGHIỆM DÙNG LƯU BIẾN KẾ THEO DÕI SỰ BIẾN THIÊN CÁC THÔNG
SỐ ĐỘ NHỚT, NGƯỠNG CHẢY CỦA VỮA BÊ-TÔNG TÍNH NĂNG CAO
In this paper, authors present the experimental studies of rheological properties of high performance concrete. In general, rheological properties including viscosity and yeild stress report the workability of concrete material after mixing step. Authors used a coaxial with vane type rheometer in laboratory to measure the rotational moment of the prepared HPC material. Obtained results showed the compressive strength of such HPC around 120 MPa after 28 days of curing period. Measured vicosity and yeild stress increases over time in the period of 0-100 minutes. 70 minutes after mixing, the studied mixture of HPC lost the workability considering the large variation of both vicosity and yeild stress values.