{"title":"双三相转六相输电线路故障分析","authors":"Mohd Wazir Mustafa, M. R. Ahmad, Hussain Shareef","doi":"10.1109/IPEC.2005.207059","DOIUrl":null,"url":null,"abstract":"High phase order transmission system is being considered a viable alternative for increasing the power transmission capability of overhead electric power transmission over existing right-of-way. This paper presents the faults analysis of six-phase transmission system. In this context, fault analysis has been conducted on the Goudey-Oakdale 2-bus test system. The results of these investigations are presented in the form of typical time responses. The PSCAD/EMTDC is used for the simulation studies","PeriodicalId":164802,"journal":{"name":"2005 International Power Engineering Conference","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"Fault analysis on double three-phase to six-phase converted transmission line\",\"authors\":\"Mohd Wazir Mustafa, M. R. Ahmad, Hussain Shareef\",\"doi\":\"10.1109/IPEC.2005.207059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High phase order transmission system is being considered a viable alternative for increasing the power transmission capability of overhead electric power transmission over existing right-of-way. This paper presents the faults analysis of six-phase transmission system. In this context, fault analysis has been conducted on the Goudey-Oakdale 2-bus test system. The results of these investigations are presented in the form of typical time responses. The PSCAD/EMTDC is used for the simulation studies\",\"PeriodicalId\":164802,\"journal\":{\"name\":\"2005 International Power Engineering Conference\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEC.2005.207059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEC.2005.207059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fault analysis on double three-phase to six-phase converted transmission line
High phase order transmission system is being considered a viable alternative for increasing the power transmission capability of overhead electric power transmission over existing right-of-way. This paper presents the faults analysis of six-phase transmission system. In this context, fault analysis has been conducted on the Goudey-Oakdale 2-bus test system. The results of these investigations are presented in the form of typical time responses. The PSCAD/EMTDC is used for the simulation studies