{"title":"钢丝绳漏磁场检测的仿真分析与实验研究","authors":"Hongyao Wang, Jie Tian, Z. Tian, H. Guo, Jian-Wu Ma, Yang Wang","doi":"10.1784/insi.2023.65.4.203","DOIUrl":null,"url":null,"abstract":"As a key bearing component, steel wire ropes suffer from partial wire breakage, broken strands and other types of damage during long-term continuous use. In this study, a magnetic flux circuit was constructed around a wire rope, an excitation detection device and an air gap. The relationship\n between the direction and angle of the magnetic line of force on the damaged end face was analysed and the waveforms of the inverted U-shaped and M-shaped leakage flux signals and their transition intervals were determined. Following this, focusing on the influence of factors such as the length\n of the damage, the cross-sectional area and the lift-off value on the magnetic flux leakage signal, the changes in the wave width and the peak value under different variables were analysed and the distribution law of the leakage magnetic field around the wire rope damage under different control\n variables was determined.","PeriodicalId":344397,"journal":{"name":"Insight - Non-Destructive Testing and Condition Monitoring","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulation analysis and experimental investigation of wire rope leakage magnetic field detection\",\"authors\":\"Hongyao Wang, Jie Tian, Z. Tian, H. Guo, Jian-Wu Ma, Yang Wang\",\"doi\":\"10.1784/insi.2023.65.4.203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As a key bearing component, steel wire ropes suffer from partial wire breakage, broken strands and other types of damage during long-term continuous use. In this study, a magnetic flux circuit was constructed around a wire rope, an excitation detection device and an air gap. The relationship\\n between the direction and angle of the magnetic line of force on the damaged end face was analysed and the waveforms of the inverted U-shaped and M-shaped leakage flux signals and their transition intervals were determined. Following this, focusing on the influence of factors such as the length\\n of the damage, the cross-sectional area and the lift-off value on the magnetic flux leakage signal, the changes in the wave width and the peak value under different variables were analysed and the distribution law of the leakage magnetic field around the wire rope damage under different control\\n variables was determined.\",\"PeriodicalId\":344397,\"journal\":{\"name\":\"Insight - Non-Destructive Testing and Condition Monitoring\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Insight - Non-Destructive Testing and Condition Monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1784/insi.2023.65.4.203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Insight - Non-Destructive Testing and Condition Monitoring","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1784/insi.2023.65.4.203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

钢丝绳作为关键的承载部件,在长期连续使用过程中会出现部分断丝、断股等类型的损坏。在本研究中,在钢丝绳、励磁检测装置和气隙周围构建磁通回路。分析了损伤端面磁力线方向与角度的关系,确定了倒u型和倒m型泄漏磁通信号的波形及其过渡区间。接着,重点研究损伤长度、截面积、升离值等因素对漏磁信号的影响,分析了不同变量下的波宽和峰值变化,确定了不同控制变量下钢丝绳损伤周围漏磁场的分布规律。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simulation analysis and experimental investigation of wire rope leakage magnetic field detection
As a key bearing component, steel wire ropes suffer from partial wire breakage, broken strands and other types of damage during long-term continuous use. In this study, a magnetic flux circuit was constructed around a wire rope, an excitation detection device and an air gap. The relationship between the direction and angle of the magnetic line of force on the damaged end face was analysed and the waveforms of the inverted U-shaped and M-shaped leakage flux signals and their transition intervals were determined. Following this, focusing on the influence of factors such as the length of the damage, the cross-sectional area and the lift-off value on the magnetic flux leakage signal, the changes in the wave width and the peak value under different variables were analysed and the distribution law of the leakage magnetic field around the wire rope damage under different control variables was determined.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信