Deni Randito Siallagan, Achmad Aprizal Ghozali, Bagus Tri Andana, Cindrawaty Lesmana, Cintiya Dewanti Santoputri, L. Azizah, Dave Vian Nurzaqi, Mohamad Nurfian Rachmat, Krismanto Kusbiantoro, Leonardo Leonardo, Ferlina Sugata
{"title":"Jamblang村公共建筑可行性视觉调查","authors":"Deni Randito Siallagan, Achmad Aprizal Ghozali, Bagus Tri Andana, Cindrawaty Lesmana, Cintiya Dewanti Santoputri, L. Azizah, Dave Vian Nurzaqi, Mohamad Nurfian Rachmat, Krismanto Kusbiantoro, Leonardo Leonardo, Ferlina Sugata","doi":"10.33087/civronlit.v8i1.107","DOIUrl":null,"url":null,"abstract":"Many functional old buildings and geological condition in Indonesia are prone to disasters, hence, the investigation is needed whether those buildings are still feasible to use. Periodic inspection is one of the methods to review the buildings by standard provisions. In this study, a survey was carried out based on Permen PU No. 16/RTM/2010 and Rapid Visual Screening (FEMA P-154). Both methods were used a special form that investigates the building visually. The purpose of the study was to investigate the existing building by reviewing the damage level of building components from the structural, architectural, mechanical, and electrical aspects, as well as to seismic hazards. Based on the Minister of Public Works Regulation Number 16/RTM/2010, the results show that there are several weathered wood columns and beams, cracked walls, and many piping and electrical that are no longer functioning. Based on Rapid Visual Screening (FEMA P-154), the final value of form level 2 is 0,2 which is similar with the SMin value, which indicating that the condition of the meeting building in Jamblang Village is categorized as prone to seismic hazards, therefore, the structure strengthening is required.","PeriodicalId":256098,"journal":{"name":"Jurnal Civronlit Unbari","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigasi Visual Kelayakan Bangunan Publik di Desa Jamblang\",\"authors\":\"Deni Randito Siallagan, Achmad Aprizal Ghozali, Bagus Tri Andana, Cindrawaty Lesmana, Cintiya Dewanti Santoputri, L. Azizah, Dave Vian Nurzaqi, Mohamad Nurfian Rachmat, Krismanto Kusbiantoro, Leonardo Leonardo, Ferlina Sugata\",\"doi\":\"10.33087/civronlit.v8i1.107\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many functional old buildings and geological condition in Indonesia are prone to disasters, hence, the investigation is needed whether those buildings are still feasible to use. Periodic inspection is one of the methods to review the buildings by standard provisions. In this study, a survey was carried out based on Permen PU No. 16/RTM/2010 and Rapid Visual Screening (FEMA P-154). Both methods were used a special form that investigates the building visually. The purpose of the study was to investigate the existing building by reviewing the damage level of building components from the structural, architectural, mechanical, and electrical aspects, as well as to seismic hazards. Based on the Minister of Public Works Regulation Number 16/RTM/2010, the results show that there are several weathered wood columns and beams, cracked walls, and many piping and electrical that are no longer functioning. Based on Rapid Visual Screening (FEMA P-154), the final value of form level 2 is 0,2 which is similar with the SMin value, which indicating that the condition of the meeting building in Jamblang Village is categorized as prone to seismic hazards, therefore, the structure strengthening is required.\",\"PeriodicalId\":256098,\"journal\":{\"name\":\"Jurnal Civronlit Unbari\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Civronlit Unbari\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33087/civronlit.v8i1.107\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Civronlit Unbari","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33087/civronlit.v8i1.107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
印度尼西亚许多具有功能的老建筑和地质条件容易发生灾害,因此需要调查这些建筑是否仍然可以使用。定期检查是按标准规定对建筑物进行审查的方法之一。本研究基于Permen PU No. 16/RTM/2010和快速视觉筛选(FEMA P-154)进行调查。这两种方法都采用了一种特殊的形式,在视觉上考察了建筑。这项研究的目的是通过从结构、建筑、机械和电气方面审查建筑部件的损坏程度以及地震危险来调查现有建筑。根据公共工程部长第16/RTM/2010号条例,结果显示有几根风化的木柱和梁,墙壁开裂,许多管道和电气设备不再运行。根据快速视觉筛选(FEMA P-154),形式2的最终值为0,2,与SMin值相似,表明Jamblang村会议大楼的状况属于地震易发危险,因此需要进行结构加固。
Investigasi Visual Kelayakan Bangunan Publik di Desa Jamblang
Many functional old buildings and geological condition in Indonesia are prone to disasters, hence, the investigation is needed whether those buildings are still feasible to use. Periodic inspection is one of the methods to review the buildings by standard provisions. In this study, a survey was carried out based on Permen PU No. 16/RTM/2010 and Rapid Visual Screening (FEMA P-154). Both methods were used a special form that investigates the building visually. The purpose of the study was to investigate the existing building by reviewing the damage level of building components from the structural, architectural, mechanical, and electrical aspects, as well as to seismic hazards. Based on the Minister of Public Works Regulation Number 16/RTM/2010, the results show that there are several weathered wood columns and beams, cracked walls, and many piping and electrical that are no longer functioning. Based on Rapid Visual Screening (FEMA P-154), the final value of form level 2 is 0,2 which is similar with the SMin value, which indicating that the condition of the meeting building in Jamblang Village is categorized as prone to seismic hazards, therefore, the structure strengthening is required.