锯木厂运营对电能质量的影响:以梅伦斯基北方木材锯木厂为例

A. G. Raji, J. M. vanColler
{"title":"锯木厂运营对电能质量的影响:以梅伦斯基北方木材锯木厂为例","authors":"A. G. Raji, J. M. vanColler","doi":"10.1109/POWERAFRICA.2016.7556592","DOIUrl":null,"url":null,"abstract":"Sawmill loads are disturbing loads. When connected to a power system, they constitute sources of harmonics, voltage fluctuations and flicker. In this paper, measurements of power quality parameters carried out in a case study of MERENSKY Northern Timbers Sawmill Ltd at Tzaneen, Limpopo Province of South Africa are reported. The report indicates that, due to some mitigation measures implemented by the plant operator, Pst flicker levels were substantially in compliance with NRS 048-2 requirements. On the other hand, Plt values were found to be high. Two mathematical models were developed for the large multi-rip sawmill plant. First, a constant impedance model was developed from the measurements. Then, a third-order induction motor model was formulated. The models are suitable for use independently in simulation studies to determine rough equipment immunity and other specifications during the planning stages of supply networks to sawmills.","PeriodicalId":177444,"journal":{"name":"2016 IEEE PES PowerAfrica","volume":"2473 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The impact of Sawmill operations on power quality: Case study of Merensky Northern Timbers Sawmill Ltd\",\"authors\":\"A. G. Raji, J. M. vanColler\",\"doi\":\"10.1109/POWERAFRICA.2016.7556592\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sawmill loads are disturbing loads. When connected to a power system, they constitute sources of harmonics, voltage fluctuations and flicker. In this paper, measurements of power quality parameters carried out in a case study of MERENSKY Northern Timbers Sawmill Ltd at Tzaneen, Limpopo Province of South Africa are reported. The report indicates that, due to some mitigation measures implemented by the plant operator, Pst flicker levels were substantially in compliance with NRS 048-2 requirements. On the other hand, Plt values were found to be high. Two mathematical models were developed for the large multi-rip sawmill plant. First, a constant impedance model was developed from the measurements. Then, a third-order induction motor model was formulated. The models are suitable for use independently in simulation studies to determine rough equipment immunity and other specifications during the planning stages of supply networks to sawmills.\",\"PeriodicalId\":177444,\"journal\":{\"name\":\"2016 IEEE PES PowerAfrica\",\"volume\":\"2473 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE PES PowerAfrica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERAFRICA.2016.7556592\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE PES PowerAfrica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERAFRICA.2016.7556592","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

锯木厂的负荷是令人不安的负荷。当连接到电力系统时,它们构成谐波、电压波动和闪烁的来源。本文报道了在南非林波波省Tzaneen的MERENSKY Northern timber Sawmill Ltd的一个案例研究中进行的电能质量参数测量。报告指出,由于电厂运营商采取了一些缓解措施,Pst闪烁水平基本上符合NRS 048-2的要求。另一方面,发现Plt值很高。建立了大型多径锯木厂的数学模型。首先,根据测量结果建立了恒定阻抗模型。然后,建立了三阶感应电机模型。该模型适用于在锯木厂供应网络规划阶段确定粗设备抗扰度和其他规格的仿真研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The impact of Sawmill operations on power quality: Case study of Merensky Northern Timbers Sawmill Ltd
Sawmill loads are disturbing loads. When connected to a power system, they constitute sources of harmonics, voltage fluctuations and flicker. In this paper, measurements of power quality parameters carried out in a case study of MERENSKY Northern Timbers Sawmill Ltd at Tzaneen, Limpopo Province of South Africa are reported. The report indicates that, due to some mitigation measures implemented by the plant operator, Pst flicker levels were substantially in compliance with NRS 048-2 requirements. On the other hand, Plt values were found to be high. Two mathematical models were developed for the large multi-rip sawmill plant. First, a constant impedance model was developed from the measurements. Then, a third-order induction motor model was formulated. The models are suitable for use independently in simulation studies to determine rough equipment immunity and other specifications during the planning stages of supply networks to sawmills.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信