在实际工作条件下,利用双端口ABCD网络方法对无LISN的电磁干扰测量进行评估

Kangrong Li, K. See
{"title":"在实际工作条件下,利用双端口ABCD网络方法对无LISN的电磁干扰测量进行评估","authors":"Kangrong Li, K. See","doi":"10.1109/APEMC.2015.7175407","DOIUrl":null,"url":null,"abstract":"To demonstrate the impact of the line impedance stabilization network (LISN) on conducted electromagnetic interference (EMI) measurement, an in-circuit impedance extraction method based on inductive coupling approach is developed to extract the common mode (CM) and the differential mode (DM) noise impedances of AC mains, LISN, and switched-mode power supply (SMPS) under operating condition. By treating two inductive coupling probes and the device-under-test (DUT) for impedance extraction as three cascaded two-port ABCD networks, the CM and DM noise impedances can be extracted with ease. The extracted CM/DM noise impedance of AC mains is compared with the extracted SMPS and LISN CM/DM noise impedances, respectively. By analyzing the impedance comparisons, the impact of LISN on conducted EMI measurement for EMI filter design under real operating condition is evaluated. Finally, the evaluation is validated with the conducted EMI currents measured with and without LISN.","PeriodicalId":325138,"journal":{"name":"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)","volume":"602 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Evaluation of conducted EMI measurement without LISN using two-port ABCD network approach for EMI filter design under real operating condition\",\"authors\":\"Kangrong Li, K. See\",\"doi\":\"10.1109/APEMC.2015.7175407\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To demonstrate the impact of the line impedance stabilization network (LISN) on conducted electromagnetic interference (EMI) measurement, an in-circuit impedance extraction method based on inductive coupling approach is developed to extract the common mode (CM) and the differential mode (DM) noise impedances of AC mains, LISN, and switched-mode power supply (SMPS) under operating condition. By treating two inductive coupling probes and the device-under-test (DUT) for impedance extraction as three cascaded two-port ABCD networks, the CM and DM noise impedances can be extracted with ease. The extracted CM/DM noise impedance of AC mains is compared with the extracted SMPS and LISN CM/DM noise impedances, respectively. By analyzing the impedance comparisons, the impact of LISN on conducted EMI measurement for EMI filter design under real operating condition is evaluated. Finally, the evaluation is validated with the conducted EMI currents measured with and without LISN.\",\"PeriodicalId\":325138,\"journal\":{\"name\":\"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)\",\"volume\":\"602 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEMC.2015.7175407\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Asia-Pacific Symposium on Electromagnetic Compatibility (APEMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEMC.2015.7175407","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

为了验证线路阻抗稳定网络(LISN)对传导电磁干扰(EMI)测量的影响,提出了一种基于电感耦合的线路阻抗提取方法,提取交流市电、LISN和开关电源(SMPS)在工作状态下的共模(CM)和差模(DM)噪声阻抗。通过将两个电感耦合探头和用于阻抗提取的被测设备(DUT)视为三个级联的双端口ABCD网络,可以轻松提取CM和DM噪声阻抗。将提取的交流市电CM/DM噪声阻抗分别与提取的SMPS和LISN CM/DM噪声阻抗进行比较。通过阻抗对比分析,评估了LISN对实际工作条件下EMI滤波器设计中传导EMI测量的影响。最后,通过使用和不使用LISN测量的传导EMI电流来验证评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of conducted EMI measurement without LISN using two-port ABCD network approach for EMI filter design under real operating condition
To demonstrate the impact of the line impedance stabilization network (LISN) on conducted electromagnetic interference (EMI) measurement, an in-circuit impedance extraction method based on inductive coupling approach is developed to extract the common mode (CM) and the differential mode (DM) noise impedances of AC mains, LISN, and switched-mode power supply (SMPS) under operating condition. By treating two inductive coupling probes and the device-under-test (DUT) for impedance extraction as three cascaded two-port ABCD networks, the CM and DM noise impedances can be extracted with ease. The extracted CM/DM noise impedance of AC mains is compared with the extracted SMPS and LISN CM/DM noise impedances, respectively. By analyzing the impedance comparisons, the impact of LISN on conducted EMI measurement for EMI filter design under real operating condition is evaluated. Finally, the evaluation is validated with the conducted EMI currents measured with and without LISN.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信