{"title":"肌肉刺激和热压迫在康复中的测量","authors":"N. Chirakanphaisarn, Thadsanee Thongkanluang","doi":"10.1109/ICECCE52056.2021.9514198","DOIUrl":null,"url":null,"abstract":"This research is to study the electric muscle stimulation system and hot compress. As well as focusing on building tools for applications in rehabilitation medicine and physical therapy. The neuromuscular system is an important mechanism in human life. In the event that the muscles are stressed or contracted while the subject is recovering, the need for recovery and stimulation tools is an important part of the physical therapy. We designed electrical circuits for automatic control and used an ARDUINO microcontroller to connect analog and digital ports to transmit and receive clinical parameters. The number of voluntary subjects was 20. Each subject remembered to perform 5 stimulation sessions for 10 minutes. Total period that the researcher collects data is approximately 3 months. The trials were based on ethical studies in humans, where trials and researches showed that subjects were 980% satisfied with very few side effects, and subjects had improved muscle development.","PeriodicalId":302947,"journal":{"name":"2021 International Conference on Electrical, Communication, and Computer Engineering (ICECCE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of Muscle Stimulation and Hot Compression for Rehabilitation\",\"authors\":\"N. Chirakanphaisarn, Thadsanee Thongkanluang\",\"doi\":\"10.1109/ICECCE52056.2021.9514198\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research is to study the electric muscle stimulation system and hot compress. As well as focusing on building tools for applications in rehabilitation medicine and physical therapy. The neuromuscular system is an important mechanism in human life. In the event that the muscles are stressed or contracted while the subject is recovering, the need for recovery and stimulation tools is an important part of the physical therapy. We designed electrical circuits for automatic control and used an ARDUINO microcontroller to connect analog and digital ports to transmit and receive clinical parameters. The number of voluntary subjects was 20. Each subject remembered to perform 5 stimulation sessions for 10 minutes. Total period that the researcher collects data is approximately 3 months. The trials were based on ethical studies in humans, where trials and researches showed that subjects were 980% satisfied with very few side effects, and subjects had improved muscle development.\",\"PeriodicalId\":302947,\"journal\":{\"name\":\"2021 International Conference on Electrical, Communication, and Computer Engineering (ICECCE)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electrical, Communication, and Computer Engineering (ICECCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECCE52056.2021.9514198\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical, Communication, and Computer Engineering (ICECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECCE52056.2021.9514198","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Measurement of Muscle Stimulation and Hot Compression for Rehabilitation
This research is to study the electric muscle stimulation system and hot compress. As well as focusing on building tools for applications in rehabilitation medicine and physical therapy. The neuromuscular system is an important mechanism in human life. In the event that the muscles are stressed or contracted while the subject is recovering, the need for recovery and stimulation tools is an important part of the physical therapy. We designed electrical circuits for automatic control and used an ARDUINO microcontroller to connect analog and digital ports to transmit and receive clinical parameters. The number of voluntary subjects was 20. Each subject remembered to perform 5 stimulation sessions for 10 minutes. Total period that the researcher collects data is approximately 3 months. The trials were based on ethical studies in humans, where trials and researches showed that subjects were 980% satisfied with very few side effects, and subjects had improved muscle development.