E. Kuantama, L. Setyawan, J. Darma
{"title":"利用短讯服务发出早期洪水警报","authors":"E. Kuantama, L. Setyawan, J. Darma","doi":"10.1109/ICSENGT.2012.6339359","DOIUrl":null,"url":null,"abstract":"Early flood alerts system is use to create a tool to measure water level, which powered by solar cell panel. The system is supported by microcontroller and GSM modem to send the measured data via SMS (Short Message Service) into two specific clients' phone numbers that have previously been inputted into the system. Besides the capability to predict the remaining time before the flood, this system can also detect three types of water level: early flood level, flood level and low tide level after the flood with a maximum water level detection of four meters. This system focused on an accurate measurement of the height of the water level and sending a warning message of the threshold height set before to the clients. For each of water level, the system will send three messages for each client number. The setting for client phone numbers and the water level can be programmed by sending the SMS that has been formatted in the system. The early flood alerts system is based on ATMEL AT89S51 microcontroller and the measurement of the water level is processed by ultrasonic HC-SR04.","PeriodicalId":325365,"journal":{"name":"2012 International Conference on System Engineering and Technology (ICSET)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"Early flood alerts using Short Message Service (SMS)\",\"authors\":\"E. Kuantama, L. Setyawan, J. Darma\",\"doi\":\"10.1109/ICSENGT.2012.6339359\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Early flood alerts system is use to create a tool to measure water level, which powered by solar cell panel. The system is supported by microcontroller and GSM modem to send the measured data via SMS (Short Message Service) into two specific clients' phone numbers that have previously been inputted into the system. Besides the capability to predict the remaining time before the flood, this system can also detect three types of water level: early flood level, flood level and low tide level after the flood with a maximum water level detection of four meters. This system focused on an accurate measurement of the height of the water level and sending a warning message of the threshold height set before to the clients. For each of water level, the system will send three messages for each client number. The setting for client phone numbers and the water level can be programmed by sending the SMS that has been formatted in the system. The early flood alerts system is based on ATMEL AT89S51 microcontroller and the measurement of the water level is processed by ultrasonic HC-SR04.\",\"PeriodicalId\":325365,\"journal\":{\"name\":\"2012 International Conference on System Engineering and Technology (ICSET)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on System Engineering and Technology (ICSET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENGT.2012.6339359\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on System Engineering and Technology (ICSET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENGT.2012.6339359","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

摘要

早期洪水预警系统是利用太阳能电池板供电,创建一个测量水位的工具。该系统由单片机和GSM调制解调器支持,将测量数据通过SMS(短消息服务)发送到预先输入系统的两个特定客户的电话号码中。该系统除了具有预测洪水前剩余时间的能力外,还可以检测三种类型的水位:洪水前期水位、洪水水位和洪水后的低潮水位,最大水位检测为4米。该系统的重点是准确测量水位高度,并将之前设置的阈值高度警告信息发送给客户端。对于每个水位,系统将为每个客户端号码发送三条消息。客户端电话号码和水位的设置可以通过发送系统中已格式化的短信进行编程。该洪水预警系统以ATMEL AT89S51单片机为核心,采用超声波HC-SR04对水位进行测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Early flood alerts using Short Message Service (SMS)
Early flood alerts system is use to create a tool to measure water level, which powered by solar cell panel. The system is supported by microcontroller and GSM modem to send the measured data via SMS (Short Message Service) into two specific clients' phone numbers that have previously been inputted into the system. Besides the capability to predict the remaining time before the flood, this system can also detect three types of water level: early flood level, flood level and low tide level after the flood with a maximum water level detection of four meters. This system focused on an accurate measurement of the height of the water level and sending a warning message of the threshold height set before to the clients. For each of water level, the system will send three messages for each client number. The setting for client phone numbers and the water level can be programmed by sending the SMS that has been formatted in the system. The early flood alerts system is based on ATMEL AT89S51 microcontroller and the measurement of the water level is processed by ultrasonic HC-SR04.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信