{"title":"[术后氮损失]。","authors":"J M Müller,&nbsp;A S Jerke,&nbsp;U Wolters","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Total nitrogen excretion was studied prospectively in 54 surgical patients during the first and second postoperative day by the Chemiluminescence method. The results were compared to three different methods for approximation of the total nitrogen excretion. Daily total nitrogen excretion was 13.13 +/- 5.7 g after peripheral vascular procedures, 15.97 +/- 8.1 g after major surgical procedures and 20.42 +/- 5.2 g in septic patients. The assessment of total nitrogen excretion by the three other methods underestimated real nitrogen losses by 20-52%. The nitrogen concentration in various secretions was relatively constant. We conclude that measuring the urine nitrogen losses only and adjusting them for the calculation of the total nitrogen excretion by several factors in incorrect. Direct measurement of total nitrogen excretion is too costly for the use in daily clinical practice.</p>","PeriodicalId":77545,"journal":{"name":"Infusionstherapie (Basel, Switzerland)","volume":"18 3","pages":"109-12"},"PeriodicalIF":0.0000,"publicationDate":"1991-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Postoperative nitrogen loss].\",\"authors\":\"J M Müller,&nbsp;A S Jerke,&nbsp;U Wolters\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Total nitrogen excretion was studied prospectively in 54 surgical patients during the first and second postoperative day by the Chemiluminescence method. The results were compared to three different methods for approximation of the total nitrogen excretion. Daily total nitrogen excretion was 13.13 +/- 5.7 g after peripheral vascular procedures, 15.97 +/- 8.1 g after major surgical procedures and 20.42 +/- 5.2 g in septic patients. The assessment of total nitrogen excretion by the three other methods underestimated real nitrogen losses by 20-52%. The nitrogen concentration in various secretions was relatively constant. We conclude that measuring the urine nitrogen losses only and adjusting them for the calculation of the total nitrogen excretion by several factors in incorrect. Direct measurement of total nitrogen excretion is too costly for the use in daily clinical practice.</p>\",\"PeriodicalId\":77545,\"journal\":{\"name\":\"Infusionstherapie (Basel, Switzerland)\",\"volume\":\"18 3\",\"pages\":\"109-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Infusionstherapie (Basel, Switzerland)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infusionstherapie (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用化学发光法对54例手术患者术后第一天和第二天的总氮排泄进行前瞻性研究。结果比较了三种不同的方法近似总氮排泄。周围血管手术后每日总氮排泄量为13.13 +/- 5.7 g,大手术后为15.97 +/- 8.1 g,脓毒症患者为20.42 +/- 5.2 g。其他3种方法估算的总氮排泄量低估了实际氮损失量20 ~ 52%。各种分泌物中的氮浓度相对恒定。我们得出结论,仅测量尿氮损失,并根据几个因素对其进行调整以计算总氮排泄量是不正确的。直接测量总氮排泄量在日常临床实践中使用成本过高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Postoperative nitrogen loss].

Total nitrogen excretion was studied prospectively in 54 surgical patients during the first and second postoperative day by the Chemiluminescence method. The results were compared to three different methods for approximation of the total nitrogen excretion. Daily total nitrogen excretion was 13.13 +/- 5.7 g after peripheral vascular procedures, 15.97 +/- 8.1 g after major surgical procedures and 20.42 +/- 5.2 g in septic patients. The assessment of total nitrogen excretion by the three other methods underestimated real nitrogen losses by 20-52%. The nitrogen concentration in various secretions was relatively constant. We conclude that measuring the urine nitrogen losses only and adjusting them for the calculation of the total nitrogen excretion by several factors in incorrect. Direct measurement of total nitrogen excretion is too costly for the use in daily clinical practice.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信