Tobias Brudermueller, F. Wirth, Andreas Weigert, T. Staake
{"title":"可变和固定速度热泵与智能仪表数据的自动区分","authors":"Tobias Brudermueller, F. Wirth, Andreas Weigert, T. Staake","doi":"10.1109/SmartGridComm52983.2022.9961055","DOIUrl":null,"url":null,"abstract":"With the increasing prevalence of heat pumps in private households, the need for optimization is growing. At the same time, the growing number of active smart electricity meters generates data that can be used for remote monitoring. In this paper, we focus on the automatic differentiation between fixed speed and variable speed heat pumps using smart meter data. This distinction is relevant because it is necessary for evaluating the state or cyclic behavior of a heat pump. In addition, identifying fixed speed heat pumps is important because they are known to be the less efficient systems and therefore may be preferred targets in energy efficiency or replacement campaigns. Our methods are applied to electricity data from 171 Swiss households with a resolution of 15 minutes. In this setting, a K-Nearest Neighbor model achieves a mean AUC of 0.976 compared to 0.5 of a biased random guess model.","PeriodicalId":252202,"journal":{"name":"2022 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Automatic Differentiation of Variable and Fixed Speed Heat Pumps With Smart Meter Data\",\"authors\":\"Tobias Brudermueller, F. Wirth, Andreas Weigert, T. Staake\",\"doi\":\"10.1109/SmartGridComm52983.2022.9961055\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the increasing prevalence of heat pumps in private households, the need for optimization is growing. At the same time, the growing number of active smart electricity meters generates data that can be used for remote monitoring. In this paper, we focus on the automatic differentiation between fixed speed and variable speed heat pumps using smart meter data. This distinction is relevant because it is necessary for evaluating the state or cyclic behavior of a heat pump. In addition, identifying fixed speed heat pumps is important because they are known to be the less efficient systems and therefore may be preferred targets in energy efficiency or replacement campaigns. Our methods are applied to electricity data from 171 Swiss households with a resolution of 15 minutes. In this setting, a K-Nearest Neighbor model achieves a mean AUC of 0.976 compared to 0.5 of a biased random guess model.\",\"PeriodicalId\":252202,\"journal\":{\"name\":\"2022 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SmartGridComm52983.2022.9961055\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SmartGridComm52983.2022.9961055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Automatic Differentiation of Variable and Fixed Speed Heat Pumps With Smart Meter Data
With the increasing prevalence of heat pumps in private households, the need for optimization is growing. At the same time, the growing number of active smart electricity meters generates data that can be used for remote monitoring. In this paper, we focus on the automatic differentiation between fixed speed and variable speed heat pumps using smart meter data. This distinction is relevant because it is necessary for evaluating the state or cyclic behavior of a heat pump. In addition, identifying fixed speed heat pumps is important because they are known to be the less efficient systems and therefore may be preferred targets in energy efficiency or replacement campaigns. Our methods are applied to electricity data from 171 Swiss households with a resolution of 15 minutes. In this setting, a K-Nearest Neighbor model achieves a mean AUC of 0.976 compared to 0.5 of a biased random guess model.