{"title":"基于WAM系统的故障定位方法","authors":"Zsolt Čonka, V. Kohan, M. Kolcun, Pálfi Judith, I. Rudas","doi":"10.1109/EPE51172.2020.9269274","DOIUrl":null,"url":null,"abstract":"WAMS is the best technology for monitoring of electricity supply system. This system is helpful for operator to analyze of data from electricity supply system in real time. Purpose of this work is find and locate place of fault on electricity supply system. On simulate electricity supply system are applying three instances. On first instance are faults same, but distances of electricity supply system are different. In second instance, distances of electricity supply system are the same, but electric faults and electric arcs are different. In last instance are different distances of electricity supply, faults on network and values of electric arc. Result from instances is that it is possible to locate place of fault in one third of network distance. In other distance is this not possible with this method.","PeriodicalId":177031,"journal":{"name":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fault localization method using WAM systems\",\"authors\":\"Zsolt Čonka, V. Kohan, M. Kolcun, Pálfi Judith, I. Rudas\",\"doi\":\"10.1109/EPE51172.2020.9269274\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"WAMS is the best technology for monitoring of electricity supply system. This system is helpful for operator to analyze of data from electricity supply system in real time. Purpose of this work is find and locate place of fault on electricity supply system. On simulate electricity supply system are applying three instances. On first instance are faults same, but distances of electricity supply system are different. In second instance, distances of electricity supply system are the same, but electric faults and electric arcs are different. In last instance are different distances of electricity supply, faults on network and values of electric arc. Result from instances is that it is possible to locate place of fault in one third of network distance. In other distance is this not possible with this method.\",\"PeriodicalId\":177031,\"journal\":{\"name\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE51172.2020.9269274\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE51172.2020.9269274","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
WAMS is the best technology for monitoring of electricity supply system. This system is helpful for operator to analyze of data from electricity supply system in real time. Purpose of this work is find and locate place of fault on electricity supply system. On simulate electricity supply system are applying three instances. On first instance are faults same, but distances of electricity supply system are different. In second instance, distances of electricity supply system are the same, but electric faults and electric arcs are different. In last instance are different distances of electricity supply, faults on network and values of electric arc. Result from instances is that it is possible to locate place of fault in one third of network distance. In other distance is this not possible with this method.