一种用于医疗保健应用的高记录性能的微针阵列干式ECG电极

Fan Ye, Minghao Wang, Jiahui Xu, Mingyi Jin, Bowen Ji, Yin Chen, Yuhua Cheng, Gaofeng Wang
{"title":"一种用于医疗保健应用的高记录性能的微针阵列干式ECG电极","authors":"Fan Ye, Minghao Wang, Jiahui Xu, Mingyi Jin, Bowen Ji, Yin Chen, Yuhua Cheng, Gaofeng Wang","doi":"10.1109/IFETC53656.2022.9948534","DOIUrl":null,"url":null,"abstract":"This paper reports a microneedle array (MNA) dry electrode for electrocardiogram (ECG) recordings without skin preparation. By using back side exposure and Through Polymer Via (TPV) technology, for the first time, the SU-8 microneedle arrays are fabricated on parylene C film and bonded with commercial wet electrode cap. The device has minimal invasive and can pierce through the corneum. Compared with conventional wet electrode, the contact impedance of the MNA dry electrode is lower and the signal quality of the MNA dry electrodes is higher both at rest and after motion. Since conducting gels are not required during ECG recording, the dry electrode shows potential application in long-term clinical health monitoring.","PeriodicalId":289035,"journal":{"name":"2022 IEEE International Flexible Electronics Technology Conference (IFETC)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Microneedle Array-based Dry ECG Electrode With High Recording Performance for Healthcare Applications\",\"authors\":\"Fan Ye, Minghao Wang, Jiahui Xu, Mingyi Jin, Bowen Ji, Yin Chen, Yuhua Cheng, Gaofeng Wang\",\"doi\":\"10.1109/IFETC53656.2022.9948534\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper reports a microneedle array (MNA) dry electrode for electrocardiogram (ECG) recordings without skin preparation. By using back side exposure and Through Polymer Via (TPV) technology, for the first time, the SU-8 microneedle arrays are fabricated on parylene C film and bonded with commercial wet electrode cap. The device has minimal invasive and can pierce through the corneum. Compared with conventional wet electrode, the contact impedance of the MNA dry electrode is lower and the signal quality of the MNA dry electrodes is higher both at rest and after motion. Since conducting gels are not required during ECG recording, the dry electrode shows potential application in long-term clinical health monitoring.\",\"PeriodicalId\":289035,\"journal\":{\"name\":\"2022 IEEE International Flexible Electronics Technology Conference (IFETC)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Flexible Electronics Technology Conference (IFETC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IFETC53656.2022.9948534\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Flexible Electronics Technology Conference (IFETC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IFETC53656.2022.9948534","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文报道了一种无需皮肤准备的用于心电图记录的微针阵列(MNA)干电极。SU-8微针阵列首次采用背面暴露和Through Polymer Via (TPV)技术,在聚对二甲苯C薄膜上制备,并与商用湿电极帽结合。该装置具有极小的侵入性,可以穿透角质层。与传统的湿电极相比,MNA干电极的接触阻抗更低,静止和运动后的信号质量更高。由于在心电图记录过程中不需要导电凝胶,因此干电极在长期临床健康监测中具有潜在的应用前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Microneedle Array-based Dry ECG Electrode With High Recording Performance for Healthcare Applications
This paper reports a microneedle array (MNA) dry electrode for electrocardiogram (ECG) recordings without skin preparation. By using back side exposure and Through Polymer Via (TPV) technology, for the first time, the SU-8 microneedle arrays are fabricated on parylene C film and bonded with commercial wet electrode cap. The device has minimal invasive and can pierce through the corneum. Compared with conventional wet electrode, the contact impedance of the MNA dry electrode is lower and the signal quality of the MNA dry electrodes is higher both at rest and after motion. Since conducting gels are not required during ECG recording, the dry electrode shows potential application in long-term clinical health monitoring.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信