TMGe探测器在高能脉冲x射线断层成像中的应用

P. Mathy, J. Girard, G. Thomas
{"title":"TMGe探测器在高能脉冲x射线断层成像中的应用","authors":"P. Mathy, J. Girard, G. Thomas","doi":"10.1109/ICDL.1990.202878","DOIUrl":null,"url":null,"abstract":"A TMGe detector designed for high-energy tomography has been successfully tested on a 100-Hz pulsed X-ray beam produced by a 8-MeV linear accelerator. A dynamic range of five decades has been measured, corresponding to 25-cm lead attenuation, with a maximum dose rate of 0.43 rad/s. The ratio between the electronic pulse current and the ionic interpulse current, mostly dependent on the duty cycle, was improved by means of electronics integrating during the pulse and just before. TMGe has been demonstrated to be an interesting detecting medium for fan-beam tomography, where a large number of very homogeneous, high-dynamic-range cells is required.<<ETX>>","PeriodicalId":193137,"journal":{"name":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","volume":"15 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Application of a TMGe detector to high energy pulsed X-ray tomography\",\"authors\":\"P. Mathy, J. Girard, G. Thomas\",\"doi\":\"10.1109/ICDL.1990.202878\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A TMGe detector designed for high-energy tomography has been successfully tested on a 100-Hz pulsed X-ray beam produced by a 8-MeV linear accelerator. A dynamic range of five decades has been measured, corresponding to 25-cm lead attenuation, with a maximum dose rate of 0.43 rad/s. The ratio between the electronic pulse current and the ionic interpulse current, mostly dependent on the duty cycle, was improved by means of electronics integrating during the pulse and just before. TMGe has been demonstrated to be an interesting detecting medium for fan-beam tomography, where a large number of very homogeneous, high-dynamic-range cells is required.<<ETX>>\",\"PeriodicalId\":193137,\"journal\":{\"name\":\"10th International Conference on Conduction and Breakdown in Dielectric Liquids\",\"volume\":\"15 1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"10th International Conference on Conduction and Breakdown in Dielectric Liquids\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICDL.1990.202878\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"10th International Conference on Conduction and Breakdown in Dielectric Liquids","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDL.1990.202878","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

设计了一种用于高能断层扫描的TMGe探测器,成功地在由8mev直线加速器产生的100 hz脉冲x射线束上进行了测试。测量了50年的动态范围,对应于25厘米的铅衰减,最大剂量率为0.43拉德/秒。电子脉冲电流和离子脉冲间电流之间的比率主要取决于占空比,通过在脉冲期间和之前进行电子积分来改善。TMGe已被证明是扇形波束断层成像的一种有趣的检测介质,在这种情况下,需要大量非常均匀、高动态范围的单元。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of a TMGe detector to high energy pulsed X-ray tomography
A TMGe detector designed for high-energy tomography has been successfully tested on a 100-Hz pulsed X-ray beam produced by a 8-MeV linear accelerator. A dynamic range of five decades has been measured, corresponding to 25-cm lead attenuation, with a maximum dose rate of 0.43 rad/s. The ratio between the electronic pulse current and the ionic interpulse current, mostly dependent on the duty cycle, was improved by means of electronics integrating during the pulse and just before. TMGe has been demonstrated to be an interesting detecting medium for fan-beam tomography, where a large number of very homogeneous, high-dynamic-range cells is required.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信