{"title":"采用SF/sub / interrupter技术的传输交换的新改进","authors":"B. Berner, J. Rostron","doi":"10.1109/TDC.2001.971254","DOIUrl":null,"url":null,"abstract":"The use of load break switches and sectionalizers to perform switching operations is common in the distribution circuits of electrical power systems. The functional need to isolate local regions of the transmission grid is expanding and, as a result, a new class of cost effective and reliable switching devices is needed. This paper discusses some applications where the capabilities of a transmission class switching device are employed. The SF/sub 6/ interrupter solves transmission class switching reliability concerns by utilizing a single break interrupter for voltages of 72.5 kV through 242 kV. The new design configuration increases the ampacity ratings available in cost effective transmission class switching devices. Several application descriptions and cost comparisons are included in the paper.","PeriodicalId":182269,"journal":{"name":"2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New improvements in transmission switching using SF/sub 6/ interrupter technology\",\"authors\":\"B. Berner, J. Rostron\",\"doi\":\"10.1109/TDC.2001.971254\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The use of load break switches and sectionalizers to perform switching operations is common in the distribution circuits of electrical power systems. The functional need to isolate local regions of the transmission grid is expanding and, as a result, a new class of cost effective and reliable switching devices is needed. This paper discusses some applications where the capabilities of a transmission class switching device are employed. The SF/sub 6/ interrupter solves transmission class switching reliability concerns by utilizing a single break interrupter for voltages of 72.5 kV through 242 kV. The new design configuration increases the ampacity ratings available in cost effective transmission class switching devices. Several application descriptions and cost comparisons are included in the paper.\",\"PeriodicalId\":182269,\"journal\":{\"name\":\"2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TDC.2001.971254\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.2001.971254","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
New improvements in transmission switching using SF/sub 6/ interrupter technology
The use of load break switches and sectionalizers to perform switching operations is common in the distribution circuits of electrical power systems. The functional need to isolate local regions of the transmission grid is expanding and, as a result, a new class of cost effective and reliable switching devices is needed. This paper discusses some applications where the capabilities of a transmission class switching device are employed. The SF/sub 6/ interrupter solves transmission class switching reliability concerns by utilizing a single break interrupter for voltages of 72.5 kV through 242 kV. The new design configuration increases the ampacity ratings available in cost effective transmission class switching devices. Several application descriptions and cost comparisons are included in the paper.