提高接口毫瓦限值对维护电压安全的有效性

S. Greene, M. Glavic
{"title":"提高接口毫瓦限值对维护电压安全的有效性","authors":"S. Greene, M. Glavic","doi":"10.1109/td43745.2022.9817004","DOIUrl":null,"url":null,"abstract":"Interface MW limits are commonly used as surrogates for voltage constraints in DC power flow models. This work proposes a simple improvement to accepted practice so that the interface MW limits better represent actual voltage vulnerability. Weights are assigned to the individual lines in the interface so that the weighted interface MW flows have the same sensitivity to real power injections as the underlying voltage constraints. Calculation of the weights requires the solution of a small dimensional linear regression equation and is of slight computational burden. The weighted interface MW limit is demonstrated to be an accurate proxy for low voltage limits to inter-area transfers using the Nordic test system.","PeriodicalId":241987,"journal":{"name":"2022 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Increasing the Effectiveness of Interface MW Limits for Maintaining Voltage Security\",\"authors\":\"S. Greene, M. Glavic\",\"doi\":\"10.1109/td43745.2022.9817004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Interface MW limits are commonly used as surrogates for voltage constraints in DC power flow models. This work proposes a simple improvement to accepted practice so that the interface MW limits better represent actual voltage vulnerability. Weights are assigned to the individual lines in the interface so that the weighted interface MW flows have the same sensitivity to real power injections as the underlying voltage constraints. Calculation of the weights requires the solution of a small dimensional linear regression equation and is of slight computational burden. The weighted interface MW limit is demonstrated to be an accurate proxy for low voltage limits to inter-area transfers using the Nordic test system.\",\"PeriodicalId\":241987,\"journal\":{\"name\":\"2022 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/td43745.2022.9817004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE/PES Transmission and Distribution Conference and Exposition (T&D)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/td43745.2022.9817004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在直流潮流模型中,接口兆瓦限值通常用作电压约束的替代。这项工作提出了一个简单的改进,以接受的做法,使接口兆瓦限值更好地代表实际电压脆弱性。将权重分配给界面中的单个线路,以便加权界面MW流对实际功率注入具有与潜在电压约束相同的灵敏度。权重的计算需要求解一个小维线性回归方程,计算量很小。使用北欧测试系统,加权界面MW限值被证明是区域间传输的低电压限值的准确代理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Increasing the Effectiveness of Interface MW Limits for Maintaining Voltage Security
Interface MW limits are commonly used as surrogates for voltage constraints in DC power flow models. This work proposes a simple improvement to accepted practice so that the interface MW limits better represent actual voltage vulnerability. Weights are assigned to the individual lines in the interface so that the weighted interface MW flows have the same sensitivity to real power injections as the underlying voltage constraints. Calculation of the weights requires the solution of a small dimensional linear regression equation and is of slight computational burden. The weighted interface MW limit is demonstrated to be an accurate proxy for low voltage limits to inter-area transfers using the Nordic test system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信