{"title":"基于自然坐标的光伏发电系统零电压穿越","authors":"Y. Xiaoling, Hu Song, Cai Hao, He Weiguo","doi":"10.1109/YAC.2017.7967448","DOIUrl":null,"url":null,"abstract":"According to national standards, large-scale photovoltaic grid-connected inverters must have zero-voltage ride through (ZVRT) capability. This paper presents a ZVRT control strategy based on natural coordinate. Complexity of the control strategy is reduced due to saving phase-locked loop and eliminating coordinate transformation. The ZVRT control of grid-connected photovoltaic inverter under symmetrical and asymmetrical faults is discussed respectively. The simulation results show the rationality and effectiveness of the control strategy under the two different fault conditions.","PeriodicalId":232358,"journal":{"name":"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Zero-voltage ride through of photovoltaic generation system based on natural coordinate\",\"authors\":\"Y. Xiaoling, Hu Song, Cai Hao, He Weiguo\",\"doi\":\"10.1109/YAC.2017.7967448\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"According to national standards, large-scale photovoltaic grid-connected inverters must have zero-voltage ride through (ZVRT) capability. This paper presents a ZVRT control strategy based on natural coordinate. Complexity of the control strategy is reduced due to saving phase-locked loop and eliminating coordinate transformation. The ZVRT control of grid-connected photovoltaic inverter under symmetrical and asymmetrical faults is discussed respectively. The simulation results show the rationality and effectiveness of the control strategy under the two different fault conditions.\",\"PeriodicalId\":232358,\"journal\":{\"name\":\"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)\",\"volume\":\"58 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/YAC.2017.7967448\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/YAC.2017.7967448","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Zero-voltage ride through of photovoltaic generation system based on natural coordinate
According to national standards, large-scale photovoltaic grid-connected inverters must have zero-voltage ride through (ZVRT) capability. This paper presents a ZVRT control strategy based on natural coordinate. Complexity of the control strategy is reduced due to saving phase-locked loop and eliminating coordinate transformation. The ZVRT control of grid-connected photovoltaic inverter under symmetrical and asymmetrical faults is discussed respectively. The simulation results show the rationality and effectiveness of the control strategy under the two different fault conditions.