电容薄膜中直至击穿的电阻和吸收电流的测量

Chunchuan Xu, S. Boggs
{"title":"电容薄膜中直至击穿的电阻和吸收电流的测量","authors":"Chunchuan Xu, S. Boggs","doi":"10.1109/ELINSL.2006.1665304","DOIUrl":null,"url":null,"abstract":"An electronic system with active feedback has been developed to facilitate measurement of resistive currents in polymer films up to breakdown. The system cancels the capacitive current actively to facilitate the measurement of the resistive current. The measured current is the result of the very rapid relaxation from a capacitive field distribution to a resistive field distribution at very high fields approaching breakdown. If the material were truly homogeneous, the resistive and capacitive field distributions would be the same. Most polymers are semicrystalline, with crystallites which have much lower conductivity than the amorphous regions with the result that the capacitive and resistive distributions are not the same. Absorption current data up to breakdown (~700 V/m) are presented for biaxially oriented polypropylene (BOPP) made by both the tenter and bubble process. These data are compared with measurements of polystyrene capacitor film which is amorphous. Transient nonlinear finite element analysis computer simulations are presented in a companion paper","PeriodicalId":427638,"journal":{"name":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Measurement of resistive and absorption currents in capacitor films up to breakdown\",\"authors\":\"Chunchuan Xu, S. Boggs\",\"doi\":\"10.1109/ELINSL.2006.1665304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An electronic system with active feedback has been developed to facilitate measurement of resistive currents in polymer films up to breakdown. The system cancels the capacitive current actively to facilitate the measurement of the resistive current. The measured current is the result of the very rapid relaxation from a capacitive field distribution to a resistive field distribution at very high fields approaching breakdown. If the material were truly homogeneous, the resistive and capacitive field distributions would be the same. Most polymers are semicrystalline, with crystallites which have much lower conductivity than the amorphous regions with the result that the capacitive and resistive distributions are not the same. Absorption current data up to breakdown (~700 V/m) are presented for biaxially oriented polypropylene (BOPP) made by both the tenter and bubble process. These data are compared with measurements of polystyrene capacitor film which is amorphous. Transient nonlinear finite element analysis computer simulations are presented in a companion paper\",\"PeriodicalId\":427638,\"journal\":{\"name\":\"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-06-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2006.1665304\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2006 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2006.1665304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

开发了一种具有主动反馈的电子系统,以方便测量聚合物薄膜中直至击穿的电阻电流。该系统主动消除容性电流,方便电阻电流的测量。测量到的电流是在接近击穿的非常高的磁场下,从电容场分布迅速弛豫到电阻场分布的结果。如果材料是真正均匀的,那么电阻场和电容场的分布将是相同的。大多数聚合物是半晶的,晶体的电导率比非晶区域低得多,导致其电容和电阻分布不相同。介绍了用压缩法和气泡法制备的双轴取向聚丙烯(BOPP)在击穿前(~700 V/m)的吸收电流数据。这些数据与非晶聚苯乙烯电容器薄膜的测量结果进行了比较。在另一篇论文中介绍了瞬态非线性有限元分析的计算机模拟
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement of resistive and absorption currents in capacitor films up to breakdown
An electronic system with active feedback has been developed to facilitate measurement of resistive currents in polymer films up to breakdown. The system cancels the capacitive current actively to facilitate the measurement of the resistive current. The measured current is the result of the very rapid relaxation from a capacitive field distribution to a resistive field distribution at very high fields approaching breakdown. If the material were truly homogeneous, the resistive and capacitive field distributions would be the same. Most polymers are semicrystalline, with crystallites which have much lower conductivity than the amorphous regions with the result that the capacitive and resistive distributions are not the same. Absorption current data up to breakdown (~700 V/m) are presented for biaxially oriented polypropylene (BOPP) made by both the tenter and bubble process. These data are compared with measurements of polystyrene capacitor film which is amorphous. Transient nonlinear finite element analysis computer simulations are presented in a companion paper
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信