基于小波变换的并网风电场电能质量分析——电能质量扰动研究

K. Bhadane, M. Ballal, R. Moharil
{"title":"基于小波变换的并网风电场电能质量分析——电能质量扰动研究","authors":"K. Bhadane, M. Ballal, R. Moharil","doi":"10.1109/ICAEE.2014.6838544","DOIUrl":null,"url":null,"abstract":"In Maharashtra, the heavy penetration level of grid connected wind energy has been used and due to this, the power quality of electric power system gets affected. This paper is described the Power Quality Disturbance Analysis of Grid Connected Wind Energy by using wavelet Transform. The effect of wind speed on power quality of grid connected wind energy of a case study system has been described. due to increased the number of grid connected Induction generators, the requirement of reactive power is increased, voltage level is decreased and system power factor get decreased. This paper shows that, how the different power quality disturbances are identify by using wavelet transform and their analysis is explained. This paper is described the impact of different wind speed on different power quality issues of grid connected wind energy. The Energy losses due to power quality disturbance of grid connected wind energy are concluded.","PeriodicalId":151739,"journal":{"name":"2014 International Conference on Advances in Electrical Engineering (ICAEE)","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Wavelet transform based power quality analysis of grid connected wind farm - An investigation of Power Quality Disturbances\",\"authors\":\"K. Bhadane, M. Ballal, R. Moharil\",\"doi\":\"10.1109/ICAEE.2014.6838544\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In Maharashtra, the heavy penetration level of grid connected wind energy has been used and due to this, the power quality of electric power system gets affected. This paper is described the Power Quality Disturbance Analysis of Grid Connected Wind Energy by using wavelet Transform. The effect of wind speed on power quality of grid connected wind energy of a case study system has been described. due to increased the number of grid connected Induction generators, the requirement of reactive power is increased, voltage level is decreased and system power factor get decreased. This paper shows that, how the different power quality disturbances are identify by using wavelet transform and their analysis is explained. This paper is described the impact of different wind speed on different power quality issues of grid connected wind energy. The Energy losses due to power quality disturbance of grid connected wind energy are concluded.\",\"PeriodicalId\":151739,\"journal\":{\"name\":\"2014 International Conference on Advances in Electrical Engineering (ICAEE)\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Advances in Electrical Engineering (ICAEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAEE.2014.6838544\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Advances in Electrical Engineering (ICAEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAEE.2014.6838544","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在马哈拉施特拉邦,风电并网普及率高,影响了电力系统的电能质量。本文介绍了用小波变换分析并网风电电能质量扰动的方法。本文描述了风速对并网风电系统电能质量的影响。由于并网感应发电机数量的增加,对无功功率的要求增加,电压水平降低,系统功率因数降低。本文阐述了如何利用小波变换识别不同的电能质量扰动,并对其进行了分析。本文描述了不同风速对并网风电不同电能质量问题的影响。总结了并网风电因电能质量扰动造成的能量损失。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wavelet transform based power quality analysis of grid connected wind farm - An investigation of Power Quality Disturbances
In Maharashtra, the heavy penetration level of grid connected wind energy has been used and due to this, the power quality of electric power system gets affected. This paper is described the Power Quality Disturbance Analysis of Grid Connected Wind Energy by using wavelet Transform. The effect of wind speed on power quality of grid connected wind energy of a case study system has been described. due to increased the number of grid connected Induction generators, the requirement of reactive power is increased, voltage level is decreased and system power factor get decreased. This paper shows that, how the different power quality disturbances are identify by using wavelet transform and their analysis is explained. This paper is described the impact of different wind speed on different power quality issues of grid connected wind energy. The Energy losses due to power quality disturbance of grid connected wind energy are concluded.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信