{"title":"retrospecs膜测试和检查系统","authors":"","doi":"10.1177/109719639602000203","DOIUrl":null,"url":null,"abstract":"Commercial membrane systems control water and air leakage through the building envelope, however, these membrane systems are only as effective as the quality of the installation. We have set the stage for detecting water and air leakage problems in a localized area. Installation deficiencies or imperfections are most common at seams, component junctions, T-joints, and penetrations such as screws or masonry ties. The most structurally critical elements of the building envelope are therefore the most vulnerable to air and water leakage-induced damage. Retro-Specs Ltd. of Winnipeg introduced a tool to the North American commercial construction market, which focuses directly on this problem, locating leakage points during construction. The AIRSURE testing unit is a single-operator device which isolates an individual detail, applies a pressure differential across the membrane, and provides a visual means of locatmg a point of leakage. The patented test method takes only seconds, and is performed as follows:","PeriodicalId":435154,"journal":{"name":"Journal of Thermal Envelope and Building Science","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Retro-Specs Membrane Testing and Inspection System\",\"authors\":\"\",\"doi\":\"10.1177/109719639602000203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Commercial membrane systems control water and air leakage through the building envelope, however, these membrane systems are only as effective as the quality of the installation. We have set the stage for detecting water and air leakage problems in a localized area. Installation deficiencies or imperfections are most common at seams, component junctions, T-joints, and penetrations such as screws or masonry ties. The most structurally critical elements of the building envelope are therefore the most vulnerable to air and water leakage-induced damage. Retro-Specs Ltd. of Winnipeg introduced a tool to the North American commercial construction market, which focuses directly on this problem, locating leakage points during construction. The AIRSURE testing unit is a single-operator device which isolates an individual detail, applies a pressure differential across the membrane, and provides a visual means of locatmg a point of leakage. The patented test method takes only seconds, and is performed as follows:\",\"PeriodicalId\":435154,\"journal\":{\"name\":\"Journal of Thermal Envelope and Building Science\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Thermal Envelope and Building Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/109719639602000203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Envelope and Building Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/109719639602000203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

商业膜系统通过建筑围护结构控制水和空气的泄漏,然而,这些膜系统的效果取决于安装的质量。我们已经在局部区域设置了检测水和空气泄漏问题的平台。安装缺陷或缺陷最常见于接缝、组件连接处、t形接头和穿透处,如螺钉或砌体连接。因此,建筑围护结构中最关键的结构元素最容易受到空气和水泄漏引起的损害。温尼伯的Retro-Specs有限公司向北美商业建筑市场推出了一种工具,该工具直接关注这个问题,在施工过程中定位泄漏点。AIRSURE测试装置是一种单人操作装置,可以隔离单个细节,在膜上施加压差,并提供定位泄漏点的视觉手段。本专利的测试方法仅需几秒钟,操作步骤如下:
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Retro-Specs Membrane Testing and Inspection System
Commercial membrane systems control water and air leakage through the building envelope, however, these membrane systems are only as effective as the quality of the installation. We have set the stage for detecting water and air leakage problems in a localized area. Installation deficiencies or imperfections are most common at seams, component junctions, T-joints, and penetrations such as screws or masonry ties. The most structurally critical elements of the building envelope are therefore the most vulnerable to air and water leakage-induced damage. Retro-Specs Ltd. of Winnipeg introduced a tool to the North American commercial construction market, which focuses directly on this problem, locating leakage points during construction. The AIRSURE testing unit is a single-operator device which isolates an individual detail, applies a pressure differential across the membrane, and provides a visual means of locatmg a point of leakage. The patented test method takes only seconds, and is performed as follows:
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信