{"title":"钢结构建筑与CFT & CFST柱组合建筑抗震性能比较研究","authors":"Selvan V","doi":"10.23880/nnoa-16000225","DOIUrl":null,"url":null,"abstract":"In this paper a comparative study is done on Steel building & Composite building with CFT, CFT with stiffeners, CFDST Hollow & CFDST column. Seismic Analysis of (B+G+9) building is done in both Equivalent Static method & Response Spectrum method using ETABS software & Optimum Composite column is obtained from Parameter 1 (Steel Ratio, Buckling Load, Plastic Resistance, H/T Ratio), Parameter 2 (Displacement, Story Drift, Base Shear, Overturning Moment, Story Stiffness), Parameter3 (Moment of Inertia, C/S Area, Total Weight, Total Tonnage).","PeriodicalId":299890,"journal":{"name":"Nanomedicine & Nanotechnology Open Access","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Study on Seismic Performance of Steel Building & Composite Building with CFT & CFST Column\",\"authors\":\"Selvan V\",\"doi\":\"10.23880/nnoa-16000225\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a comparative study is done on Steel building & Composite building with CFT, CFT with stiffeners, CFDST Hollow & CFDST column. Seismic Analysis of (B+G+9) building is done in both Equivalent Static method & Response Spectrum method using ETABS software & Optimum Composite column is obtained from Parameter 1 (Steel Ratio, Buckling Load, Plastic Resistance, H/T Ratio), Parameter 2 (Displacement, Story Drift, Base Shear, Overturning Moment, Story Stiffness), Parameter3 (Moment of Inertia, C/S Area, Total Weight, Total Tonnage).\",\"PeriodicalId\":299890,\"journal\":{\"name\":\"Nanomedicine & Nanotechnology Open Access\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nanomedicine & Nanotechnology Open Access\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23880/nnoa-16000225\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanomedicine & Nanotechnology Open Access","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23880/nnoa-16000225","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparative Study on Seismic Performance of Steel Building & Composite Building with CFT & CFST Column
In this paper a comparative study is done on Steel building & Composite building with CFT, CFT with stiffeners, CFDST Hollow & CFDST column. Seismic Analysis of (B+G+9) building is done in both Equivalent Static method & Response Spectrum method using ETABS software & Optimum Composite column is obtained from Parameter 1 (Steel Ratio, Buckling Load, Plastic Resistance, H/T Ratio), Parameter 2 (Displacement, Story Drift, Base Shear, Overturning Moment, Story Stiffness), Parameter3 (Moment of Inertia, C/S Area, Total Weight, Total Tonnage).