设计一个监测和控制天然气泄漏的Elpiji系统与NodeMCU esp266微调

Nyoman Gede Adrama, G. Ramadhan, I. Sukadana
{"title":"设计一个监测和控制天然气泄漏的Elpiji系统与NodeMCU esp266微调","authors":"Nyoman Gede Adrama, G. Ramadhan, I. Sukadana","doi":"10.38043/telsinas.v5i1.3754","DOIUrl":null,"url":null,"abstract":"The role of information technology in security is also getting stronger, this is shown by the company's innovation to use technology to support their security equipment. LPG cylinder explosions are usually caused by human error. To minimize human error in the gas installation system, I designed and built a prototype of an LPG gas leak detector with an MQ-2 gas sensor and NodeMCU ESP8266 microcontroller as an input and output controller. The input is an MQ-2 gas sensor and the output is a solenoid valve. The gas sensor detects an increased ambient gas leak odor condition. If the gas odor has exceeded the maximum predetermined limit, the NodeMCU microcontroller will provide an indicator on the panel then send a message to the smartphone via the telegram application and turn off the gas line.","PeriodicalId":252670,"journal":{"name":"Jurnal Ilmiah Telsinas Elektro, Sipil dan Teknik Informasi","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Rancang Bangun Sistem Monitoring Dan Kontrol Kebocoran Gas Elpiji dengan Mikrokontroler NodeMCU ESP8266\",\"authors\":\"Nyoman Gede Adrama, G. Ramadhan, I. Sukadana\",\"doi\":\"10.38043/telsinas.v5i1.3754\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The role of information technology in security is also getting stronger, this is shown by the company's innovation to use technology to support their security equipment. LPG cylinder explosions are usually caused by human error. To minimize human error in the gas installation system, I designed and built a prototype of an LPG gas leak detector with an MQ-2 gas sensor and NodeMCU ESP8266 microcontroller as an input and output controller. The input is an MQ-2 gas sensor and the output is a solenoid valve. The gas sensor detects an increased ambient gas leak odor condition. If the gas odor has exceeded the maximum predetermined limit, the NodeMCU microcontroller will provide an indicator on the panel then send a message to the smartphone via the telegram application and turn off the gas line.\",\"PeriodicalId\":252670,\"journal\":{\"name\":\"Jurnal Ilmiah Telsinas Elektro, Sipil dan Teknik Informasi\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Ilmiah Telsinas Elektro, Sipil dan Teknik Informasi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.38043/telsinas.v5i1.3754\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Ilmiah Telsinas Elektro, Sipil dan Teknik Informasi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.38043/telsinas.v5i1.3754","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

信息技术在安全中的作用也越来越强,这表现在公司创新地使用技术来支持他们的安全设备。液化石油气气瓶爆炸通常由人为失误引起。为了最大限度地减少气体安装系统中的人为错误,我设计并构建了一个LPG气体泄漏探测器的原型,该探测器采用MQ-2气体传感器和NodeMCU ESP8266微控制器作为输入和输出控制器。输入为MQ-2气体传感器,输出为电磁阀。气体传感器检测到环境气体泄漏气味的增加。如果气体气味超过了预定的最大限度,NodeMCU微控制器将在面板上提供一个指示灯,然后通过电报应用程序向智能手机发送消息并关闭燃气管道。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rancang Bangun Sistem Monitoring Dan Kontrol Kebocoran Gas Elpiji dengan Mikrokontroler NodeMCU ESP8266
The role of information technology in security is also getting stronger, this is shown by the company's innovation to use technology to support their security equipment. LPG cylinder explosions are usually caused by human error. To minimize human error in the gas installation system, I designed and built a prototype of an LPG gas leak detector with an MQ-2 gas sensor and NodeMCU ESP8266 microcontroller as an input and output controller. The input is an MQ-2 gas sensor and the output is a solenoid valve. The gas sensor detects an increased ambient gas leak odor condition. If the gas odor has exceeded the maximum predetermined limit, the NodeMCU microcontroller will provide an indicator on the panel then send a message to the smartphone via the telegram application and turn off the gas line.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信