Yao Qu, Mingming Shi, Shiyu Sun, Bin Li, Juntao Fei, Xiong Yang
{"title":"基于配电网可调资源协调控制的三相不平衡控制方法","authors":"Yao Qu, Mingming Shi, Shiyu Sun, Bin Li, Juntao Fei, Xiong Yang","doi":"10.1109/AEEES56888.2023.10114130","DOIUrl":null,"url":null,"abstract":"Aiming at the problem of three-phase voltage unbalance caused by the probabilistic output of single-phase distributed photovoltaic (DPV) in distribution network, the method of coordinated operation of DPV reactive power regulation and capacitor bank to control three-phase voltage unbalance is studied. The relationship between the reactive power of single-phase DPV output and the three-phase unbalance degree of the grid-connected common connection point is analyzed. The influence of the reactive power of the capacitor bank on the three-phase unbalance degree of each node is deduced. The output value of DPV is calculated based on the prediction results of solar irradiance. Aiming at the three-phase unbalance of the common connection point not exceeding 2%, the reactive power regulation is given according to the derivation relationship between the reactive power of each equipment and the three-phase unbalance, so as to ensure that the three-phase unbalance in the station area is limited within the required range. Finally, the correctness and effectiveness of the method are verified by the data calculation of a station in Jiangsu Province.","PeriodicalId":272114,"journal":{"name":"2023 5th Asia Energy and Electrical Engineering Symposium (AEEES)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three Phase Unbalance Control Method Based on Coordinated Control of Adjustable Resources in Distribution Network\",\"authors\":\"Yao Qu, Mingming Shi, Shiyu Sun, Bin Li, Juntao Fei, Xiong Yang\",\"doi\":\"10.1109/AEEES56888.2023.10114130\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aiming at the problem of three-phase voltage unbalance caused by the probabilistic output of single-phase distributed photovoltaic (DPV) in distribution network, the method of coordinated operation of DPV reactive power regulation and capacitor bank to control three-phase voltage unbalance is studied. The relationship between the reactive power of single-phase DPV output and the three-phase unbalance degree of the grid-connected common connection point is analyzed. The influence of the reactive power of the capacitor bank on the three-phase unbalance degree of each node is deduced. The output value of DPV is calculated based on the prediction results of solar irradiance. Aiming at the three-phase unbalance of the common connection point not exceeding 2%, the reactive power regulation is given according to the derivation relationship between the reactive power of each equipment and the three-phase unbalance, so as to ensure that the three-phase unbalance in the station area is limited within the required range. Finally, the correctness and effectiveness of the method are verified by the data calculation of a station in Jiangsu Province.\",\"PeriodicalId\":272114,\"journal\":{\"name\":\"2023 5th Asia Energy and Electrical Engineering Symposium (AEEES)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 5th Asia Energy and Electrical Engineering Symposium (AEEES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEEES56888.2023.10114130\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 5th Asia Energy and Electrical Engineering Symposium (AEEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEEES56888.2023.10114130","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Three Phase Unbalance Control Method Based on Coordinated Control of Adjustable Resources in Distribution Network
Aiming at the problem of three-phase voltage unbalance caused by the probabilistic output of single-phase distributed photovoltaic (DPV) in distribution network, the method of coordinated operation of DPV reactive power regulation and capacitor bank to control three-phase voltage unbalance is studied. The relationship between the reactive power of single-phase DPV output and the three-phase unbalance degree of the grid-connected common connection point is analyzed. The influence of the reactive power of the capacitor bank on the three-phase unbalance degree of each node is deduced. The output value of DPV is calculated based on the prediction results of solar irradiance. Aiming at the three-phase unbalance of the common connection point not exceeding 2%, the reactive power regulation is given according to the derivation relationship between the reactive power of each equipment and the three-phase unbalance, so as to ensure that the three-phase unbalance in the station area is limited within the required range. Finally, the correctness and effectiveness of the method are verified by the data calculation of a station in Jiangsu Province.