{"title":"建筑紧急疏散的运输和暖通空调系统","authors":"Andrew See, L. Michel, B. Xiong, P. Luh, Shi-Chung Chang","doi":"10.1109/COASE.2006.326909","DOIUrl":null,"url":null,"abstract":"Building emergency evacuation has long been recognized as an important problem, since safety is a major concern for building occupants. The paths selected for egress should be pressurized with fresh air through HVAC airflow control. The problem is to minimize the egress time by reconfiguring HVAC units and selecting egress paths for occupants in a building, subject to path capacities and HVAC system limitations. The interdependency of the transportation and HVAC systems and the combinatorial nature of discrete optimization make this a challenging problem. For simplicity, steady-state airflow analysis over each duct is used, and dampers are considered either fully open or fully closed. Our key idea is to make full use of traditional network flow models for egress while considering the fan power capacity as a constraint. The problem is solved by iteratively using a maxflow algorithm while exploiting dominance properties to reduce the search space. An optimized reconfiguration of the HVAC is established, resulting in significant improvements in evacuation time","PeriodicalId":116108,"journal":{"name":"2006 IEEE International Conference on Automation Science and Engineering","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Transportation and HVAC Systems for Building Emergency Evacuation\",\"authors\":\"Andrew See, L. Michel, B. Xiong, P. Luh, Shi-Chung Chang\",\"doi\":\"10.1109/COASE.2006.326909\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Building emergency evacuation has long been recognized as an important problem, since safety is a major concern for building occupants. The paths selected for egress should be pressurized with fresh air through HVAC airflow control. The problem is to minimize the egress time by reconfiguring HVAC units and selecting egress paths for occupants in a building, subject to path capacities and HVAC system limitations. The interdependency of the transportation and HVAC systems and the combinatorial nature of discrete optimization make this a challenging problem. For simplicity, steady-state airflow analysis over each duct is used, and dampers are considered either fully open or fully closed. Our key idea is to make full use of traditional network flow models for egress while considering the fan power capacity as a constraint. The problem is solved by iteratively using a maxflow algorithm while exploiting dominance properties to reduce the search space. An optimized reconfiguration of the HVAC is established, resulting in significant improvements in evacuation time\",\"PeriodicalId\":116108,\"journal\":{\"name\":\"2006 IEEE International Conference on Automation Science and Engineering\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE International Conference on Automation Science and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COASE.2006.326909\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Conference on Automation Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COASE.2006.326909","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

建筑物紧急疏散一直被认为是一个重要的问题,因为安全是建筑物居住者主要关心的问题。选择的出口路径应通过暖通空调气流控制用新风加压。问题是根据路径容量和HVAC系统的限制,通过重新配置HVAC设备和为建筑物中的居住者选择出口路径来最小化出口时间。运输系统和暖通空调系统的相互依赖性以及离散优化的组合特性使这成为一个具有挑战性的问题。为简单起见,对每个管道进行稳态气流分析,并将阻尼器视为完全打开或完全关闭。我们的关键思想是充分利用传统的网络流模型进行出口,同时考虑风机功率容量作为约束。在利用优势属性减少搜索空间的同时,迭代地使用maxflow算法来解决这个问题。建立了优化的HVAC重新配置,从而大大缩短了疏散时间
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transportation and HVAC Systems for Building Emergency Evacuation
Building emergency evacuation has long been recognized as an important problem, since safety is a major concern for building occupants. The paths selected for egress should be pressurized with fresh air through HVAC airflow control. The problem is to minimize the egress time by reconfiguring HVAC units and selecting egress paths for occupants in a building, subject to path capacities and HVAC system limitations. The interdependency of the transportation and HVAC systems and the combinatorial nature of discrete optimization make this a challenging problem. For simplicity, steady-state airflow analysis over each duct is used, and dampers are considered either fully open or fully closed. Our key idea is to make full use of traditional network flow models for egress while considering the fan power capacity as a constraint. The problem is solved by iteratively using a maxflow algorithm while exploiting dominance properties to reduce the search space. An optimized reconfiguration of the HVAC is established, resulting in significant improvements in evacuation time
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信