Renan A. Bohaienko, Américo C. Bortolazzo, R. Consani, R. Vivan, Fabrício R. Silva, Simonides Consani
{"title":"加热冲洗液对往复根管锉抗循环疲劳性能的影响","authors":"Renan A. Bohaienko, Américo C. Bortolazzo, R. Consani, R. Vivan, Fabrício R. Silva, Simonides Consani","doi":"10.24018/ejdent.2022.3.5.226","DOIUrl":null,"url":null,"abstract":"\nObjectives: The aim of this study was to evaluate the effect of heated irrigating solutions on the cyclic fatigue resistance of reciprocating endodontic files.\n\n\nMaterials and Methods: Reciproc Blue, ProDesign S and X1-Blue files were immersed in the irrigating solutions 5.25% NaClO and 2% chlorhexidine digluconate gel heated in oven at 37ºC for 10 min. In same conditions, saline solution was considered as control. The following groups (n=15) were considered: RSs (Reciproc Blue + saline solution); RNa (Reciproc Blue + 5.25% NaClO); RCd (Reciproc Blue + 2% Chlorhexidine digluconate gel); PSs (ProDesign S + saline solution); PNa (ProDesign S + 5.25% NaClO); PCd (ProDesign S + 2% Chlorhexidine digluconate gel; XSs (X1-Blue + Saline solution); XNa (X1-Blue + 5.25% NaClO) and XCd (X1 Blue + 2% Chlorhexidine digluconate gel). Cyclic fatigue test was performed in a device with a 60 degrees curved canal and 5 mm radius immersed in water at 37ºC. The time for file failure was recorded in seconds to calculate the number of cycles to fracture (NCF). Data were submitted to ANOVA followed by Tukey's test (α=0.05%) comparing split plots (SPSS 26.0). \n\n\nResults: There was no statistically significant difference for NCF between irrigating solutions and control in all file types. ProDesign S showed greater and significant difference when compared to Reciproc Blue and X1 Blue in all irrigating solutions and control.\n\n\nConclusions: NCF value in each file type was not influenced by the solutions. Among file types, the NCF value was higher for ProDesign S and lower for X1-Blue in all solutions.\n\n\nClinical Relevance: Heated irrigating solutions is not a relevant factor in relation to fracture resistance of reciprocating endodontic files; however, the fracture was influenced by the file types.\n","PeriodicalId":197045,"journal":{"name":"European Journal of Dental and Oral Health","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Heated Irrigating Solutions on the Cyclic Fatigue Resistance of Reciprocating Endodontic Files\",\"authors\":\"Renan A. Bohaienko, Américo C. Bortolazzo, R. Consani, R. Vivan, Fabrício R. Silva, Simonides Consani\",\"doi\":\"10.24018/ejdent.2022.3.5.226\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\nObjectives: The aim of this study was to evaluate the effect of heated irrigating solutions on the cyclic fatigue resistance of reciprocating endodontic files.\\n\\n\\nMaterials and Methods: Reciproc Blue, ProDesign S and X1-Blue files were immersed in the irrigating solutions 5.25% NaClO and 2% chlorhexidine digluconate gel heated in oven at 37ºC for 10 min. In same conditions, saline solution was considered as control. The following groups (n=15) were considered: RSs (Reciproc Blue + saline solution); RNa (Reciproc Blue + 5.25% NaClO); RCd (Reciproc Blue + 2% Chlorhexidine digluconate gel); PSs (ProDesign S + saline solution); PNa (ProDesign S + 5.25% NaClO); PCd (ProDesign S + 2% Chlorhexidine digluconate gel; XSs (X1-Blue + Saline solution); XNa (X1-Blue + 5.25% NaClO) and XCd (X1 Blue + 2% Chlorhexidine digluconate gel). Cyclic fatigue test was performed in a device with a 60 degrees curved canal and 5 mm radius immersed in water at 37ºC. The time for file failure was recorded in seconds to calculate the number of cycles to fracture (NCF). Data were submitted to ANOVA followed by Tukey's test (α=0.05%) comparing split plots (SPSS 26.0). \\n\\n\\nResults: There was no statistically significant difference for NCF between irrigating solutions and control in all file types. ProDesign S showed greater and significant difference when compared to Reciproc Blue and X1 Blue in all irrigating solutions and control.\\n\\n\\nConclusions: NCF value in each file type was not influenced by the solutions. Among file types, the NCF value was higher for ProDesign S and lower for X1-Blue in all solutions.\\n\\n\\nClinical Relevance: Heated irrigating solutions is not a relevant factor in relation to fracture resistance of reciprocating endodontic files; however, the fracture was influenced by the file types.\\n\",\"PeriodicalId\":197045,\"journal\":{\"name\":\"European Journal of Dental and Oral Health\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Dental and Oral Health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24018/ejdent.2022.3.5.226\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Dental and Oral Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24018/ejdent.2022.3.5.226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目的:研究加热灌洗液对往复根管锉抗循环疲劳性能的影响。材料与方法:将Reciproc Blue、ProDesign S和X1-Blue锉浸入5.25% NaClO和2%二光酸氯己定凝胶的冲洗液中,37℃烤箱加热10 min。同样条件下,以生理盐水为对照。考虑以下组(n=15): RSs (Reciproc Blue +生理盐水);RNa (Reciproc Blue + 5.25% NaClO);RCd (Reciproc Blue + 2%二光酸氯己定凝胶);PSs (ProDesign S +生理盐水);PNa (ProDesign S + 5.25% NaClO);PCd (ProDesign S + 2%二光酸氯己定凝胶;XSs (X1-Blue +生理盐水溶液);XNa (X1-Blue + 5.25% NaClO)和XCd (X1 Blue + 2%二光酸氯己定凝胶)。循环疲劳试验采用60度弯管、5 mm半径的装置浸泡在37℃的水中。文件失效时间以秒为单位记录,以计算断裂周期数(NCF)。数据进行方差分析,然后进行Tukey检验(α=0.05%),比较分裂图(SPSS 26.0)。结果:在所有文件类型中,灌洗液与对照的NCF无统计学差异。与Reciproc Blue和X1 Blue相比,ProDesign S在所有灌洗液和对照中均表现出更大且显著的差异。结论:各文件类型的NCF值不受溶液的影响。在所有文件类型中,ProDesign S的NCF值较高,X1-Blue的NCF值较低。临床意义:加热冲洗液与往复根管锉的抗折性无关;然而,骨折受锉型的影响。
Effect of Heated Irrigating Solutions on the Cyclic Fatigue Resistance of Reciprocating Endodontic Files
Objectives: The aim of this study was to evaluate the effect of heated irrigating solutions on the cyclic fatigue resistance of reciprocating endodontic files.
Materials and Methods: Reciproc Blue, ProDesign S and X1-Blue files were immersed in the irrigating solutions 5.25% NaClO and 2% chlorhexidine digluconate gel heated in oven at 37ºC for 10 min. In same conditions, saline solution was considered as control. The following groups (n=15) were considered: RSs (Reciproc Blue + saline solution); RNa (Reciproc Blue + 5.25% NaClO); RCd (Reciproc Blue + 2% Chlorhexidine digluconate gel); PSs (ProDesign S + saline solution); PNa (ProDesign S + 5.25% NaClO); PCd (ProDesign S + 2% Chlorhexidine digluconate gel; XSs (X1-Blue + Saline solution); XNa (X1-Blue + 5.25% NaClO) and XCd (X1 Blue + 2% Chlorhexidine digluconate gel). Cyclic fatigue test was performed in a device with a 60 degrees curved canal and 5 mm radius immersed in water at 37ºC. The time for file failure was recorded in seconds to calculate the number of cycles to fracture (NCF). Data were submitted to ANOVA followed by Tukey's test (α=0.05%) comparing split plots (SPSS 26.0).
Results: There was no statistically significant difference for NCF between irrigating solutions and control in all file types. ProDesign S showed greater and significant difference when compared to Reciproc Blue and X1 Blue in all irrigating solutions and control.
Conclusions: NCF value in each file type was not influenced by the solutions. Among file types, the NCF value was higher for ProDesign S and lower for X1-Blue in all solutions.
Clinical Relevance: Heated irrigating solutions is not a relevant factor in relation to fracture resistance of reciprocating endodontic files; however, the fracture was influenced by the file types.