UPQC体系结构在不同负载条件下的性能分析

Sikandra Kumar Mandal, N. Singh
{"title":"UPQC体系结构在不同负载条件下的性能分析","authors":"Sikandra Kumar Mandal, N. Singh","doi":"10.24113/ijoscience.v7i8.408","DOIUrl":null,"url":null,"abstract":"The UPQC has the ability to improve the network quality at the installation site in electrical distribution networks or industrial electrical networks. The main objective of this thesis is to design a system to improve the network quality with a simplified architecture to support reactive power as well as to improve the active power available for load connections and to improve the efficiency of the system controls mentioned above. From this work, it was deduced that by developing and the inverter system with an control strategy in SVPWM, the device are proposed to improve the quality of the network can serve this goal with better results in the terms of performance and the efficiency. In this architecture can also be used in the hybrid systems, in making it more reliable. The designed system is also suitable for the delivery of different types of loads, such as non-linear load, symmetrical load, and asymmetrical load.","PeriodicalId":429424,"journal":{"name":"SMART MOVES JOURNAL IJOSCIENCE","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance Analysis of UPQC Architecture at Different Load Conditions\",\"authors\":\"Sikandra Kumar Mandal, N. Singh\",\"doi\":\"10.24113/ijoscience.v7i8.408\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The UPQC has the ability to improve the network quality at the installation site in electrical distribution networks or industrial electrical networks. The main objective of this thesis is to design a system to improve the network quality with a simplified architecture to support reactive power as well as to improve the active power available for load connections and to improve the efficiency of the system controls mentioned above. From this work, it was deduced that by developing and the inverter system with an control strategy in SVPWM, the device are proposed to improve the quality of the network can serve this goal with better results in the terms of performance and the efficiency. In this architecture can also be used in the hybrid systems, in making it more reliable. The designed system is also suitable for the delivery of different types of loads, such as non-linear load, symmetrical load, and asymmetrical load.\",\"PeriodicalId\":429424,\"journal\":{\"name\":\"SMART MOVES JOURNAL IJOSCIENCE\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SMART MOVES JOURNAL IJOSCIENCE\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24113/ijoscience.v7i8.408\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SMART MOVES JOURNAL IJOSCIENCE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24113/ijoscience.v7i8.408","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在配电网或工业电网中,UPQC具有改善安装现场网络质量的能力。本文的主要目标是设计一个系统,以简化的架构来提高网络质量,以支持无功功率,同时提高负载连接的有功功率,并提高上述系统控制的效率。研究结果表明,通过在SVPWM中开发和采用控制策略的逆变器系统,所提出的提高网络质量的装置可以在性能和效率方面达到较好的效果。在这种体系结构中也可以使用在混合系统中,使其更加可靠。所设计的系统也适用于输送不同类型的载荷,如非线性载荷、对称载荷和不对称载荷。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance Analysis of UPQC Architecture at Different Load Conditions
The UPQC has the ability to improve the network quality at the installation site in electrical distribution networks or industrial electrical networks. The main objective of this thesis is to design a system to improve the network quality with a simplified architecture to support reactive power as well as to improve the active power available for load connections and to improve the efficiency of the system controls mentioned above. From this work, it was deduced that by developing and the inverter system with an control strategy in SVPWM, the device are proposed to improve the quality of the network can serve this goal with better results in the terms of performance and the efficiency. In this architecture can also be used in the hybrid systems, in making it more reliable. The designed system is also suitable for the delivery of different types of loads, such as non-linear load, symmetrical load, and asymmetrical load.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信