{"title":"不同类型雷达探测沥青密封策略的比较研究","authors":"M. S. Karis, N. Hasim, N. M. Ali, M. F. Baharom, Arfah Ahmad, N. Abas, Mohd Zurix Bin Mohamed, Zulkarnain Mokhtar, M. Shahril","doi":"10.1109/ICED.2014.7015791","DOIUrl":null,"url":null,"abstract":"This paper analyzes the radar performance of a bitumen liquid level detection. In previous installation, radar A and B has successfully found its place to detect bitumen liquid level in tank storage. The problems occur when these two types of radar continuously give the frequent peak error in liquid level measurement output readings. With an advanced technology this research proposes of using radar C. By focusing at the frequency of error occurrence as each radar performance is continuously monitored in 8 weeks, radar A gives 55, radar B gives 19 while radar C gives 4 times. From the overall performance of usable radar based on frequency of error occurrence, the minimum error was given by radar C which makes it the most effective to be used in bitumen liquid level detection as it provided more reliable, repeatable and reasonable level measurement results value.","PeriodicalId":143806,"journal":{"name":"2014 2nd International Conference on Electronic Design (ICED)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Comparative study for bitumen containment strategy using different radar types for level detection\",\"authors\":\"M. S. Karis, N. Hasim, N. M. Ali, M. F. Baharom, Arfah Ahmad, N. Abas, Mohd Zurix Bin Mohamed, Zulkarnain Mokhtar, M. Shahril\",\"doi\":\"10.1109/ICED.2014.7015791\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper analyzes the radar performance of a bitumen liquid level detection. In previous installation, radar A and B has successfully found its place to detect bitumen liquid level in tank storage. The problems occur when these two types of radar continuously give the frequent peak error in liquid level measurement output readings. With an advanced technology this research proposes of using radar C. By focusing at the frequency of error occurrence as each radar performance is continuously monitored in 8 weeks, radar A gives 55, radar B gives 19 while radar C gives 4 times. From the overall performance of usable radar based on frequency of error occurrence, the minimum error was given by radar C which makes it the most effective to be used in bitumen liquid level detection as it provided more reliable, repeatable and reasonable level measurement results value.\",\"PeriodicalId\":143806,\"journal\":{\"name\":\"2014 2nd International Conference on Electronic Design (ICED)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 2nd International Conference on Electronic Design (ICED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICED.2014.7015791\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 2nd International Conference on Electronic Design (ICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICED.2014.7015791","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文分析了沥青液位检测的雷达性能。在之前的安装中,雷达A和雷达B已经成功地找到了检测罐内沥青液位的位置。当这两种雷达连续给出频繁的液位测量输出读数峰值误差时,就会出现问题。本研究采用先进的技术,提出使用C雷达。在连续监测每台雷达性能的8周内,通过聚焦误差发生的频率,A雷达给出55次,B雷达给出19次,C雷达给出4次。从可用雷达的总体性能来看,C雷达的误差最小,可提供更可靠、可重复、合理的液位测量结果值,是沥青液位检测中最有效的雷达。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative study for bitumen containment strategy using different radar types for level detection
This paper analyzes the radar performance of a bitumen liquid level detection. In previous installation, radar A and B has successfully found its place to detect bitumen liquid level in tank storage. The problems occur when these two types of radar continuously give the frequent peak error in liquid level measurement output readings. With an advanced technology this research proposes of using radar C. By focusing at the frequency of error occurrence as each radar performance is continuously monitored in 8 weeks, radar A gives 55, radar B gives 19 while radar C gives 4 times. From the overall performance of usable radar based on frequency of error occurrence, the minimum error was given by radar C which makes it the most effective to be used in bitumen liquid level detection as it provided more reliable, repeatable and reasonable level measurement results value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信