{"title":"利用超高频传感器定位电力变压器初放电","authors":"M. Chakravarthi, A. Giridhar, D. Sarma","doi":"10.1109/ICHVET.2019.8724280","DOIUrl":null,"url":null,"abstract":"Non-intrusive ultra high frequency detection method has been recognized as well established diagnostic tool for monitoring the condition of power transformers. This UHF method is considered as the best choice to sense the location of onsite partial discharges (PD's) in power transformer because of its good signal to noise ratio (SNR) and high sensitivity. The PD source location accuracy mainly rely on TDOA (Time differences of Arrival) of PD source and the individual four uhf sensors or sensor array placed around the transformer tank. The location of PD source is evaluated by using PSO algorithm with the set of TDOA measurements from the experiment.","PeriodicalId":165193,"journal":{"name":"2019 International Conference on High Voltage Engineering and Technology (ICHVET)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Localization of Incipient Discharge in Power Transformer Using UHF Sensor\",\"authors\":\"M. Chakravarthi, A. Giridhar, D. Sarma\",\"doi\":\"10.1109/ICHVET.2019.8724280\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Non-intrusive ultra high frequency detection method has been recognized as well established diagnostic tool for monitoring the condition of power transformers. This UHF method is considered as the best choice to sense the location of onsite partial discharges (PD's) in power transformer because of its good signal to noise ratio (SNR) and high sensitivity. The PD source location accuracy mainly rely on TDOA (Time differences of Arrival) of PD source and the individual four uhf sensors or sensor array placed around the transformer tank. The location of PD source is evaluated by using PSO algorithm with the set of TDOA measurements from the experiment.\",\"PeriodicalId\":165193,\"journal\":{\"name\":\"2019 International Conference on High Voltage Engineering and Technology (ICHVET)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on High Voltage Engineering and Technology (ICHVET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVET.2019.8724280\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on High Voltage Engineering and Technology (ICHVET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVET.2019.8724280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Localization of Incipient Discharge in Power Transformer Using UHF Sensor
Non-intrusive ultra high frequency detection method has been recognized as well established diagnostic tool for monitoring the condition of power transformers. This UHF method is considered as the best choice to sense the location of onsite partial discharges (PD's) in power transformer because of its good signal to noise ratio (SNR) and high sensitivity. The PD source location accuracy mainly rely on TDOA (Time differences of Arrival) of PD source and the individual four uhf sensors or sensor array placed around the transformer tank. The location of PD source is evaluated by using PSO algorithm with the set of TDOA measurements from the experiment.