{"title":"血管狭窄时血管壁的O/sub 2/代谢","authors":"D. Buerk, S. Dubin, K. Gealow","doi":"10.1109/NEBC.1988.19387","DOIUrl":null,"url":null,"abstract":"Vascular tissue O/sub 2/ partial pressure (PO/sub 2/) measurements with recessed cathode O/sub 2/ microelectrodes were made in the walls of isolated rabbit abdominal aortas during saline perfusion in vitro. Three months prior to the experiments, the aortic lumen was reduced by approximately 50% using a tantalum metal clip. A 2- to 3-cm segment of the abdominal aorta including the stenosis was removed and mounted in a chamber maintained at 19.9 kPa. With constant perfusion, the minimum tissue PO/sub 2/ in the wall varied axially along the segment. The minimum wall PO/sub 2/ (+or-SE) was 13.5+or-0.4 kPa at the location 5 mm upstream and 14.2+or-0.8 kPa at the location 5 mm downstream. The lowest value, 11.6+or-0.8 kPa, was found 1 mm downstream. O/sub 2/ disappearance rates (dPO/sub 2//dt) at each location were also measured after stopping perfusion to the segment. The disappearance rates varied axially, with the fastest rate, -4.1+or-0.6 kPa/min, found 1 mm upstream. At 4 and 5 mm upstream and downstream from the stenosis, the rates were essentially the same, at 2.8+or-0.3 kPa/min. The average value for O/sub 2/ metabolism at the upstream and downstream ends is 5.0*10/sup -4/ mL O/sub 2//mL tissue/min.<<ETX>>","PeriodicalId":165980,"journal":{"name":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"O/sub 2/ metabolism in blood vessel walls with stenoses\",\"authors\":\"D. Buerk, S. Dubin, K. Gealow\",\"doi\":\"10.1109/NEBC.1988.19387\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Vascular tissue O/sub 2/ partial pressure (PO/sub 2/) measurements with recessed cathode O/sub 2/ microelectrodes were made in the walls of isolated rabbit abdominal aortas during saline perfusion in vitro. Three months prior to the experiments, the aortic lumen was reduced by approximately 50% using a tantalum metal clip. A 2- to 3-cm segment of the abdominal aorta including the stenosis was removed and mounted in a chamber maintained at 19.9 kPa. With constant perfusion, the minimum tissue PO/sub 2/ in the wall varied axially along the segment. The minimum wall PO/sub 2/ (+or-SE) was 13.5+or-0.4 kPa at the location 5 mm upstream and 14.2+or-0.8 kPa at the location 5 mm downstream. The lowest value, 11.6+or-0.8 kPa, was found 1 mm downstream. O/sub 2/ disappearance rates (dPO/sub 2//dt) at each location were also measured after stopping perfusion to the segment. The disappearance rates varied axially, with the fastest rate, -4.1+or-0.6 kPa/min, found 1 mm upstream. At 4 and 5 mm upstream and downstream from the stenosis, the rates were essentially the same, at 2.8+or-0.3 kPa/min. The average value for O/sub 2/ metabolism at the upstream and downstream ends is 5.0*10/sup -4/ mL O/sub 2//mL tissue/min.<<ETX>>\",\"PeriodicalId\":165980,\"journal\":{\"name\":\"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBC.1988.19387\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1988.19387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
O/sub 2/ metabolism in blood vessel walls with stenoses
Vascular tissue O/sub 2/ partial pressure (PO/sub 2/) measurements with recessed cathode O/sub 2/ microelectrodes were made in the walls of isolated rabbit abdominal aortas during saline perfusion in vitro. Three months prior to the experiments, the aortic lumen was reduced by approximately 50% using a tantalum metal clip. A 2- to 3-cm segment of the abdominal aorta including the stenosis was removed and mounted in a chamber maintained at 19.9 kPa. With constant perfusion, the minimum tissue PO/sub 2/ in the wall varied axially along the segment. The minimum wall PO/sub 2/ (+or-SE) was 13.5+or-0.4 kPa at the location 5 mm upstream and 14.2+or-0.8 kPa at the location 5 mm downstream. The lowest value, 11.6+or-0.8 kPa, was found 1 mm downstream. O/sub 2/ disappearance rates (dPO/sub 2//dt) at each location were also measured after stopping perfusion to the segment. The disappearance rates varied axially, with the fastest rate, -4.1+or-0.6 kPa/min, found 1 mm upstream. At 4 and 5 mm upstream and downstream from the stenosis, the rates were essentially the same, at 2.8+or-0.3 kPa/min. The average value for O/sub 2/ metabolism at the upstream and downstream ends is 5.0*10/sup -4/ mL O/sub 2//mL tissue/min.<>