超声心动图评价原位心脏移植:单中心经验

N. Behzadnia, B. Kashani, M. Mirhosseini, A. Moradi, G. Radmand, Z. Ahmadi
{"title":"超声心动图评价原位心脏移植:单中心经验","authors":"N. Behzadnia, B. Kashani, M. Mirhosseini, A. Moradi, G. Radmand, Z. Ahmadi","doi":"10.5812/acvi.24391","DOIUrl":null,"url":null,"abstract":"Background: In patients with advanced heart failure, significant improvement in pharmacological and non-pharmacological treatment strategies has conferred better survival rates and quality of life. Objectives: This is a report on echocardiographic findings in heart transplantation (HTx) patients in their first 5 postoperative months. Patients and Methods: Twenty patients undergoing HTx between September 2009 and July 2010 whose clinical and echocardiographic findings had been registered monthly for 5 months after HTx were enrolled. Results: Eleven males and five females at a mean age of 33 years [range = 17-58 years] were enrolled in the study. The mean of the left ventricular ejection fraction (LVEF) was 52 ± 8.2 % and 58 ± 2.5 % on the first day and at 5 months after HTx, respectively. There was no LV enlargement at 5 months' follow-up. The right ventricle (RV) was mildly enlarged, but the reduced baseline RV function showed improvement at the 5th postoperative month (mean TAPSE was 11.7 ± 3.3 mm on the first post-HTx day versus 17.2 ± 6.3 mm after 5 months; P < 0.005). The pulmonary arterial pressure was slightly elevated at baseline, and it showed no significant decrease 5 months after HTx. More than 90% of the cases showed only mild tricuspid regurgitation at 5 months' follow-up. The tissue Doppler imaging-derived velocities of the medial and lateral mitral annuli and the tricuspid annulus demonstrated a gradual increment during the follow-up and reached their highest value at 5 months' follow-up. Conclusions: The cardiac grafts at 5 months' post-HTx follow-up were characterized by normal LV dimensions and EF. Also, RV dysfunction and tricuspid regurgitation were frequent findings, but they were not associated with the clinical signs of congestive heart failure, morbidity, and mortality in the majority of our patients.","PeriodicalId":429543,"journal":{"name":"Archives of Cardiovascular Imaging","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Echocardiographic evaluation of orthotopic heart transplantation: Single-Center experience\",\"authors\":\"N. Behzadnia, B. Kashani, M. Mirhosseini, A. Moradi, G. Radmand, Z. Ahmadi\",\"doi\":\"10.5812/acvi.24391\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: In patients with advanced heart failure, significant improvement in pharmacological and non-pharmacological treatment strategies has conferred better survival rates and quality of life. Objectives: This is a report on echocardiographic findings in heart transplantation (HTx) patients in their first 5 postoperative months. Patients and Methods: Twenty patients undergoing HTx between September 2009 and July 2010 whose clinical and echocardiographic findings had been registered monthly for 5 months after HTx were enrolled. Results: Eleven males and five females at a mean age of 33 years [range = 17-58 years] were enrolled in the study. The mean of the left ventricular ejection fraction (LVEF) was 52 ± 8.2 % and 58 ± 2.5 % on the first day and at 5 months after HTx, respectively. There was no LV enlargement at 5 months' follow-up. The right ventricle (RV) was mildly enlarged, but the reduced baseline RV function showed improvement at the 5th postoperative month (mean TAPSE was 11.7 ± 3.3 mm on the first post-HTx day versus 17.2 ± 6.3 mm after 5 months; P < 0.005). The pulmonary arterial pressure was slightly elevated at baseline, and it showed no significant decrease 5 months after HTx. More than 90% of the cases showed only mild tricuspid regurgitation at 5 months' follow-up. The tissue Doppler imaging-derived velocities of the medial and lateral mitral annuli and the tricuspid annulus demonstrated a gradual increment during the follow-up and reached their highest value at 5 months' follow-up. Conclusions: The cardiac grafts at 5 months' post-HTx follow-up were characterized by normal LV dimensions and EF. Also, RV dysfunction and tricuspid regurgitation were frequent findings, but they were not associated with the clinical signs of congestive heart failure, morbidity, and mortality in the majority of our patients.\",\"PeriodicalId\":429543,\"journal\":{\"name\":\"Archives of Cardiovascular Imaging\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Cardiovascular Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5812/acvi.24391\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Cardiovascular Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5812/acvi.24391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

背景:在晚期心力衰竭患者中,药物和非药物治疗策略的显著改善赋予了更好的生存率和生活质量。目的:报告心脏移植(HTx)患者术后5个月的超声心动图表现。患者与方法:入选2009年9月至2010年7月期间接受HTx治疗的20例患者,这些患者在HTx治疗后5个月内每月登记一次临床和超声心动图表现。结果:11名男性和5名女性被纳入研究,平均年龄33岁[范围= 17-58岁]。HTx术后第1天和5个月左室射血分数(LVEF)平均值分别为52±8.2%和58±2.5%。随访5个月未见左室扩大。右心室(RV)轻度增大,但减少的基线RV功能在术后第5个月有所改善(htx术后第一天的平均TAPSE为11.7±3.3 mm, 5个月后为17.2±6.3 mm;P < 0.005)。肺动脉压在基线时略有升高,HTx后5个月无明显下降。超过90%的病例在随访5个月时仅出现轻度三尖瓣反流。二尖瓣内、外侧环和三尖瓣环的组织多普勒成像速度在随访期间逐渐增加,并在随访5个月时达到最高值。结论:经htx术后5个月随访,心脏移植物左室尺寸和心功能正常。此外,右心室功能障碍和三尖瓣反流是常见的发现,但在我们的大多数患者中,它们与充血性心力衰竭的临床症状、发病率和死亡率无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Echocardiographic evaluation of orthotopic heart transplantation: Single-Center experience
Background: In patients with advanced heart failure, significant improvement in pharmacological and non-pharmacological treatment strategies has conferred better survival rates and quality of life. Objectives: This is a report on echocardiographic findings in heart transplantation (HTx) patients in their first 5 postoperative months. Patients and Methods: Twenty patients undergoing HTx between September 2009 and July 2010 whose clinical and echocardiographic findings had been registered monthly for 5 months after HTx were enrolled. Results: Eleven males and five females at a mean age of 33 years [range = 17-58 years] were enrolled in the study. The mean of the left ventricular ejection fraction (LVEF) was 52 ± 8.2 % and 58 ± 2.5 % on the first day and at 5 months after HTx, respectively. There was no LV enlargement at 5 months' follow-up. The right ventricle (RV) was mildly enlarged, but the reduced baseline RV function showed improvement at the 5th postoperative month (mean TAPSE was 11.7 ± 3.3 mm on the first post-HTx day versus 17.2 ± 6.3 mm after 5 months; P < 0.005). The pulmonary arterial pressure was slightly elevated at baseline, and it showed no significant decrease 5 months after HTx. More than 90% of the cases showed only mild tricuspid regurgitation at 5 months' follow-up. The tissue Doppler imaging-derived velocities of the medial and lateral mitral annuli and the tricuspid annulus demonstrated a gradual increment during the follow-up and reached their highest value at 5 months' follow-up. Conclusions: The cardiac grafts at 5 months' post-HTx follow-up were characterized by normal LV dimensions and EF. Also, RV dysfunction and tricuspid regurgitation were frequent findings, but they were not associated with the clinical signs of congestive heart failure, morbidity, and mortality in the majority of our patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信