基于圆顶识别的二维电泳图像脉冲噪声去除

Qiaofeng Ou, Huisheng Zhang, Lixin Li, Bangshu Xiong
{"title":"基于圆顶识别的二维电泳图像脉冲噪声去除","authors":"Qiaofeng Ou, Huisheng Zhang, Lixin Li, Bangshu Xiong","doi":"10.1109/BMEI.2015.7401545","DOIUrl":null,"url":null,"abstract":"Two-dimensional gel electrophoresis (2DE) images are often corrupted by impulse noise in broad sense (including various artifacts, such as fingerprints, hairs, gel cracks, strips, water stains, dust and so on). In this paper, we propose a novel adaptive directional filter (ADF) to remove impulse noise completely and accurately. Firstly, we detect the impulse noise based on the observation that the directional derivative distributions around the protein spot centers and noise pixels are very different. Then, according to the bell-shaped three-dimensional appearance of protein spots, the greatest and smallest gradient directions were used to restore the noised pixels. Lastly, the pixels adjacent to the modified pixels are iteratively detected and restored until no impulse noise is detected. Experimental results on the synthetic and real 2DE images show that the proposed method performs much better than the previous approaches.","PeriodicalId":119361,"journal":{"name":"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Impulse noise removal in two-dimensional electrophoresis images based on dome recognition\",\"authors\":\"Qiaofeng Ou, Huisheng Zhang, Lixin Li, Bangshu Xiong\",\"doi\":\"10.1109/BMEI.2015.7401545\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two-dimensional gel electrophoresis (2DE) images are often corrupted by impulse noise in broad sense (including various artifacts, such as fingerprints, hairs, gel cracks, strips, water stains, dust and so on). In this paper, we propose a novel adaptive directional filter (ADF) to remove impulse noise completely and accurately. Firstly, we detect the impulse noise based on the observation that the directional derivative distributions around the protein spot centers and noise pixels are very different. Then, according to the bell-shaped three-dimensional appearance of protein spots, the greatest and smallest gradient directions were used to restore the noised pixels. Lastly, the pixels adjacent to the modified pixels are iteratively detected and restored until no impulse noise is detected. Experimental results on the synthetic and real 2DE images show that the proposed method performs much better than the previous approaches.\",\"PeriodicalId\":119361,\"journal\":{\"name\":\"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BMEI.2015.7401545\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEI.2015.7401545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

二维凝胶电泳(2DE)图像经常受到广义脉冲噪声(包括各种人工制品,如指纹、毛发、凝胶裂纹、条带、水渍、灰尘等)的破坏。本文提出了一种新的自适应定向滤波器(ADF),可以完全准确地去除脉冲噪声。首先,我们根据观察到的蛋白质斑点中心周围的方向导数分布和噪声像素有很大的不同来检测脉冲噪声;然后,根据蛋白质斑点的钟形三维外观,利用最大和最小梯度方向恢复噪声像素。最后,迭代检测和恢复与修改后的像素相邻的像素,直到没有检测到脉冲噪声。在合成和真实2DE图像上的实验结果表明,该方法的性能明显优于以往的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impulse noise removal in two-dimensional electrophoresis images based on dome recognition
Two-dimensional gel electrophoresis (2DE) images are often corrupted by impulse noise in broad sense (including various artifacts, such as fingerprints, hairs, gel cracks, strips, water stains, dust and so on). In this paper, we propose a novel adaptive directional filter (ADF) to remove impulse noise completely and accurately. Firstly, we detect the impulse noise based on the observation that the directional derivative distributions around the protein spot centers and noise pixels are very different. Then, according to the bell-shaped three-dimensional appearance of protein spots, the greatest and smallest gradient directions were used to restore the noised pixels. Lastly, the pixels adjacent to the modified pixels are iteratively detected and restored until no impulse noise is detected. Experimental results on the synthetic and real 2DE images show that the proposed method performs much better than the previous approaches.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信