{"title":"【磨铣/火花侵蚀钛的固定齿更换】。","authors":"P D Reppel, K Böning, M Walter","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In a clinical study the accuracy of fit of 82 crowns manufactured with the Procera-system (duplication milling/spark erosion) was investigated. The average marginal space width was 71 microns. Roughness of eroded surfaces was found to be similar to that of coarsely ground metal. Below the eroded areas a zone of increased hardness with a width of approximately 20 microns was demonstrated.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 11","pages":"756-8"},"PeriodicalIF":0.0000,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Fixed tooth replacement of milled/spark eroded titanium].\",\"authors\":\"P D Reppel, K Böning, M Walter\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In a clinical study the accuracy of fit of 82 crowns manufactured with the Procera-system (duplication milling/spark erosion) was investigated. The average marginal space width was 71 microns. Roughness of eroded surfaces was found to be similar to that of coarsely ground metal. Below the eroded areas a zone of increased hardness with a width of approximately 20 microns was demonstrated.</p>\",\"PeriodicalId\":11244,\"journal\":{\"name\":\"Deutsche zahnarztliche Zeitschrift\",\"volume\":\"46 11\",\"pages\":\"756-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Deutsche zahnarztliche Zeitschrift\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche zahnarztliche Zeitschrift","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Fixed tooth replacement of milled/spark eroded titanium].
In a clinical study the accuracy of fit of 82 crowns manufactured with the Procera-system (duplication milling/spark erosion) was investigated. The average marginal space width was 71 microns. Roughness of eroded surfaces was found to be similar to that of coarsely ground metal. Below the eroded areas a zone of increased hardness with a width of approximately 20 microns was demonstrated.