【人类牙齿牙本质比电阻的研究】。

Deutsche zahnarztliche Zeitschrift Pub Date : 1991-12-01
M Gente, D Becker-Detert
{"title":"【人类牙齿牙本质比电阻的研究】。","authors":"M Gente,&nbsp;D Becker-Detert","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Electric current produced by corrosion of metals or used for diagnostic or therapeutic purposes has to pass through the dentin to reach the pulp. The electric resistance of the dentin, which influences the dentinal current intensity, is poorly documented in the literature. In this study 140 cylindrical dentin samples of human teeth were collected from four different regions of the tooth crown and their specific electrical resistance was measured. The recorded values vary with the orientation of the dentinal tubules ranging between 12.5 ohms and ohms. The linear temperature coefficient of the specific resistance is -0.0132 degrees C-1 for the temperature interval of 20 to 34 degrees C. It is assumed that the mechanism underlying electric conduction in dentin is related to the transport of ions in the dentinal fluid.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1991-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Studies on the specific electric resistance of the dentin of human teeth].\",\"authors\":\"M Gente,&nbsp;D Becker-Detert\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Electric current produced by corrosion of metals or used for diagnostic or therapeutic purposes has to pass through the dentin to reach the pulp. The electric resistance of the dentin, which influences the dentinal current intensity, is poorly documented in the literature. In this study 140 cylindrical dentin samples of human teeth were collected from four different regions of the tooth crown and their specific electrical resistance was measured. The recorded values vary with the orientation of the dentinal tubules ranging between 12.5 ohms and ohms. The linear temperature coefficient of the specific resistance is -0.0132 degrees C-1 for the temperature interval of 20 to 34 degrees C. It is assumed that the mechanism underlying electric conduction in dentin is related to the transport of ions in the dentinal fluid.</p>\",\"PeriodicalId\":11244,\"journal\":{\"name\":\"Deutsche zahnarztliche Zeitschrift\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Deutsche zahnarztliche Zeitschrift\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche zahnarztliche Zeitschrift","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由金属腐蚀产生的电流或用于诊断或治疗目的的电流必须通过牙本质到达牙髓。影响牙本质电流强度的牙本质电阻,在文献中记载甚少。本研究从人类牙冠的四个不同区域收集了140个圆柱形牙本质样本,并测量了它们的比电阻。记录值随牙本质小管方向的变化而变化,范围在12.5欧姆到欧姆之间。在20 ~ 34℃的温度区间内,比电阻的线性温度系数为-0.0132℃-1,推测牙本质内的导电机制与牙本质液中离子的运输有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Studies on the specific electric resistance of the dentin of human teeth].

Electric current produced by corrosion of metals or used for diagnostic or therapeutic purposes has to pass through the dentin to reach the pulp. The electric resistance of the dentin, which influences the dentinal current intensity, is poorly documented in the literature. In this study 140 cylindrical dentin samples of human teeth were collected from four different regions of the tooth crown and their specific electrical resistance was measured. The recorded values vary with the orientation of the dentinal tubules ranging between 12.5 ohms and ohms. The linear temperature coefficient of the specific resistance is -0.0132 degrees C-1 for the temperature interval of 20 to 34 degrees C. It is assumed that the mechanism underlying electric conduction in dentin is related to the transport of ions in the dentinal fluid.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信