基于细胞内和细胞外同步记录的脉冲检测器的比较

I. Obeid
{"title":"基于细胞内和细胞外同步记录的脉冲检测器的比较","authors":"I. Obeid","doi":"10.1109/CNE.2007.369696","DOIUrl":null,"url":null,"abstract":"The ability to accurately detect action potentials in cortical in vivo recordings is a necessary first step in any multichannel wireless brain-machine interface (BMI) data acquisition system. This work presents a comparison of simple spike detection algorithms appropriate for implementation in an autonomous low power wireless BMI chip. The detectors were applied to pre-recorded cortical extracellular potentials. A simultaneously recorded intracellular transmembrane voltage gave the precise spike times of a local neuron; these times were then used as the \"gold standard\" against which to compare the output of the spike detectors under test. In contrast to earlier work on simulated data that showed the superiority of a simple absolute value-based spike detector, this work demonstrated that the non-linear energy operator provides an effective balance between correct detections and false alarms, and that the relative difference between detection algorithms diminishes as SNR increases","PeriodicalId":427054,"journal":{"name":"2007 3rd International IEEE/EMBS Conference on Neural Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Comparison of Spike Detectors based on Simultaneous Intracellular and Extracellular Recordings\",\"authors\":\"I. Obeid\",\"doi\":\"10.1109/CNE.2007.369696\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ability to accurately detect action potentials in cortical in vivo recordings is a necessary first step in any multichannel wireless brain-machine interface (BMI) data acquisition system. This work presents a comparison of simple spike detection algorithms appropriate for implementation in an autonomous low power wireless BMI chip. The detectors were applied to pre-recorded cortical extracellular potentials. A simultaneously recorded intracellular transmembrane voltage gave the precise spike times of a local neuron; these times were then used as the \\\"gold standard\\\" against which to compare the output of the spike detectors under test. In contrast to earlier work on simulated data that showed the superiority of a simple absolute value-based spike detector, this work demonstrated that the non-linear energy operator provides an effective balance between correct detections and false alarms, and that the relative difference between detection algorithms diminishes as SNR increases\",\"PeriodicalId\":427054,\"journal\":{\"name\":\"2007 3rd International IEEE/EMBS Conference on Neural Engineering\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-05-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 3rd International IEEE/EMBS Conference on Neural Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CNE.2007.369696\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 3rd International IEEE/EMBS Conference on Neural Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CNE.2007.369696","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

在任何多通道无线脑机接口(BMI)数据采集系统中,准确检测皮层活体记录中的动作电位的能力是必要的第一步。这项工作提出了适合在自主低功耗无线BMI芯片中实现的简单尖峰检测算法的比较。检测器应用于预先记录的皮层细胞外电位。同时记录的细胞内跨膜电压给出了局部神经元的精确尖峰时间;这些时间被用作“黄金标准”,用来比较被测尖峰探测器的输出。早期在模拟数据上的工作显示了简单的基于绝对值的尖峰检测器的优越性,与此相反,这项工作表明,非线性能量算子在正确检测和假警报之间提供了有效的平衡,并且检测算法之间的相对差异随着信噪比的增加而减小
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Spike Detectors based on Simultaneous Intracellular and Extracellular Recordings
The ability to accurately detect action potentials in cortical in vivo recordings is a necessary first step in any multichannel wireless brain-machine interface (BMI) data acquisition system. This work presents a comparison of simple spike detection algorithms appropriate for implementation in an autonomous low power wireless BMI chip. The detectors were applied to pre-recorded cortical extracellular potentials. A simultaneously recorded intracellular transmembrane voltage gave the precise spike times of a local neuron; these times were then used as the "gold standard" against which to compare the output of the spike detectors under test. In contrast to earlier work on simulated data that showed the superiority of a simple absolute value-based spike detector, this work demonstrated that the non-linear energy operator provides an effective balance between correct detections and false alarms, and that the relative difference between detection algorithms diminishes as SNR increases
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信