D. Guo, D. Lathi, N. Harid, H. Griffiths, A. Haddad, A. Ainsley
{"title":"大型接地电极性能的实验研究","authors":"D. Guo, D. Lathi, N. Harid, H. Griffiths, A. Haddad, A. Ainsley","doi":"10.1109/ICHVE.2010.5640727","DOIUrl":null,"url":null,"abstract":"Analytical and numerical simulation techniques have been developed for the calculation of earth resistance/impedance and to estimate the potential distribution in the vicinity of earth electrodes. However, very little literature is available on experimental validation of these calculation techniques. To address this, a programme of experimental tests on various earth electrodes has been carried out at the lower water reservoir of a hydro pumped-storage power station in North Wales. In this paper, the earthing test facility at Dinorwig power station is described including the details of the experimental set up. The results from experimental tests on a 5mx5m earth grid, immersed in water and energised are under ac, dc and impulse, are presented. The values of measured earth resistance/impedance and water surface potential distributions are compared with those obtained from analytical calculations and detailed numerical computer simulations.","PeriodicalId":287425,"journal":{"name":"2010 International Conference on High Voltage Engineering and Application","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Experimental investigation into the performance of large-scale earthing electrodes\",\"authors\":\"D. Guo, D. Lathi, N. Harid, H. Griffiths, A. Haddad, A. Ainsley\",\"doi\":\"10.1109/ICHVE.2010.5640727\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Analytical and numerical simulation techniques have been developed for the calculation of earth resistance/impedance and to estimate the potential distribution in the vicinity of earth electrodes. However, very little literature is available on experimental validation of these calculation techniques. To address this, a programme of experimental tests on various earth electrodes has been carried out at the lower water reservoir of a hydro pumped-storage power station in North Wales. In this paper, the earthing test facility at Dinorwig power station is described including the details of the experimental set up. The results from experimental tests on a 5mx5m earth grid, immersed in water and energised are under ac, dc and impulse, are presented. The values of measured earth resistance/impedance and water surface potential distributions are compared with those obtained from analytical calculations and detailed numerical computer simulations.\",\"PeriodicalId\":287425,\"journal\":{\"name\":\"2010 International Conference on High Voltage Engineering and Application\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2010.5640727\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2010.5640727","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

分析和数值模拟技术已经发展用于计算地电阻/阻抗和估计地电极附近的电位分布。然而,关于这些计算技术的实验验证的文献很少。为了解决这一问题,在北威尔士的一个抽水蓄能电站的下部水库开展了一项各种接地电极试验方案。介绍了迪诺威格电站的接地试验装置,包括试验装置的详细情况。本文介绍了一个5mx5m的浸没在水中并通电的地网在交流、直流和冲击下的试验结果。实测的地阻/阻抗值和水面电位分布与解析计算和详细的计算机数值模拟结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental investigation into the performance of large-scale earthing electrodes
Analytical and numerical simulation techniques have been developed for the calculation of earth resistance/impedance and to estimate the potential distribution in the vicinity of earth electrodes. However, very little literature is available on experimental validation of these calculation techniques. To address this, a programme of experimental tests on various earth electrodes has been carried out at the lower water reservoir of a hydro pumped-storage power station in North Wales. In this paper, the earthing test facility at Dinorwig power station is described including the details of the experimental set up. The results from experimental tests on a 5mx5m earth grid, immersed in water and energised are under ac, dc and impulse, are presented. The values of measured earth resistance/impedance and water surface potential distributions are compared with those obtained from analytical calculations and detailed numerical computer simulations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信