利用牙科植入物制造有线植入健康监测装置

S. Hemati, Sepideh Rahmani
{"title":"利用牙科植入物制造有线植入健康监测装置","authors":"S. Hemati, Sepideh Rahmani","doi":"10.1109/HealthCom.2016.7749529","DOIUrl":null,"url":null,"abstract":"In this work, we propose a physical gateway, which resembles a modified dental implant that goes directly through gum or other soft tissues inside the oral cavity, to establish a secure and permanent connection to wired implantable health monitoring and controlling (IHMC) devices and systems. The proposed physical gateway has parts acting as external access points that have terminals for cables, wires, fiber optics, or tubes that go through the gateway to IHMC devices and systems to allow transmission of signals or materials to or from the implanted devices. This novel feature can be utilized for powering IHMC devices and systems with high functionality and computational power. Furthermore, it facilitates securely communicating with IHMC devices and systems with vital duties and allows transferring materials for refilling the tanks inside these devices and systems or transferring some samples and substances from inside body to outside without requiring additional invasive operations.","PeriodicalId":167022,"journal":{"name":"2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exploiting dental implants for creating wired implantable health monitoring devices\",\"authors\":\"S. Hemati, Sepideh Rahmani\",\"doi\":\"10.1109/HealthCom.2016.7749529\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, we propose a physical gateway, which resembles a modified dental implant that goes directly through gum or other soft tissues inside the oral cavity, to establish a secure and permanent connection to wired implantable health monitoring and controlling (IHMC) devices and systems. The proposed physical gateway has parts acting as external access points that have terminals for cables, wires, fiber optics, or tubes that go through the gateway to IHMC devices and systems to allow transmission of signals or materials to or from the implanted devices. This novel feature can be utilized for powering IHMC devices and systems with high functionality and computational power. Furthermore, it facilitates securely communicating with IHMC devices and systems with vital duties and allows transferring materials for refilling the tanks inside these devices and systems or transferring some samples and substances from inside body to outside without requiring additional invasive operations.\",\"PeriodicalId\":167022,\"journal\":{\"name\":\"2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HealthCom.2016.7749529\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HealthCom.2016.7749529","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在这项工作中,我们提出了一种物理网关,它类似于一种改良的牙种植体,直接穿过口腔内的牙龈或其他软组织,以建立与有线植入健康监测和控制(IHMC)设备和系统的安全永久连接。所建议的物理网关具有充当外部接入点的部件,其具有用于电缆、电线、光纤或管道的终端,这些终端通过网关到达IHMC设备和系统,以允许向植入设备或从植入设备传输信号或材料。这种新特性可用于为具有高功能和计算能力的IHMC设备和系统提供动力。此外,它有助于与具有重要职责的IHMC设备和系统进行安全通信,并允许在这些设备和系统内转移材料以重新填充储罐,或将一些样品和物质从体内转移到外部,而无需额外的侵入性操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Exploiting dental implants for creating wired implantable health monitoring devices
In this work, we propose a physical gateway, which resembles a modified dental implant that goes directly through gum or other soft tissues inside the oral cavity, to establish a secure and permanent connection to wired implantable health monitoring and controlling (IHMC) devices and systems. The proposed physical gateway has parts acting as external access points that have terminals for cables, wires, fiber optics, or tubes that go through the gateway to IHMC devices and systems to allow transmission of signals or materials to or from the implanted devices. This novel feature can be utilized for powering IHMC devices and systems with high functionality and computational power. Furthermore, it facilitates securely communicating with IHMC devices and systems with vital duties and allows transferring materials for refilling the tanks inside these devices and systems or transferring some samples and substances from inside body to outside without requiring additional invasive operations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信