{"title":"弱网格中多点测量的亚毫秒瞬态分析","authors":"A. Matthee, N. Moonen, F. Leferink","doi":"10.1109/EMCEUROPE48519.2020.9245718","DOIUrl":null,"url":null,"abstract":"Peak loads determine the rated capacity of islanded grid power supplies. This often results in non-optimal running conditions in terms of cost, efficiency or size footprint. Presented in this paper is a method of in-depth analysis of very fast sub-millisecond transient behaviour performed between sub-systems and supply in a low-inertia grids. Using this method, time domain measurements can be analysed to potentially achieve electromagnetic compatibility. Synchronised current and voltage measurements are possible, with offsets in the sub-milliseconds and high sample rates of tens of Mega-samples per second. A demonstration of a weak grid is presented showing effects of linear and non-linear loads on the supply source and power quality.","PeriodicalId":332251,"journal":{"name":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Sub-Millisecond Transient Analysis with Multi-Point Measurement in Weak Grids\",\"authors\":\"A. Matthee, N. Moonen, F. Leferink\",\"doi\":\"10.1109/EMCEUROPE48519.2020.9245718\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Peak loads determine the rated capacity of islanded grid power supplies. This often results in non-optimal running conditions in terms of cost, efficiency or size footprint. Presented in this paper is a method of in-depth analysis of very fast sub-millisecond transient behaviour performed between sub-systems and supply in a low-inertia grids. Using this method, time domain measurements can be analysed to potentially achieve electromagnetic compatibility. Synchronised current and voltage measurements are possible, with offsets in the sub-milliseconds and high sample rates of tens of Mega-samples per second. A demonstration of a weak grid is presented showing effects of linear and non-linear loads on the supply source and power quality.\",\"PeriodicalId\":332251,\"journal\":{\"name\":\"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCEUROPE48519.2020.9245718\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE48519.2020.9245718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Sub-Millisecond Transient Analysis with Multi-Point Measurement in Weak Grids
Peak loads determine the rated capacity of islanded grid power supplies. This often results in non-optimal running conditions in terms of cost, efficiency or size footprint. Presented in this paper is a method of in-depth analysis of very fast sub-millisecond transient behaviour performed between sub-systems and supply in a low-inertia grids. Using this method, time domain measurements can be analysed to potentially achieve electromagnetic compatibility. Synchronised current and voltage measurements are possible, with offsets in the sub-milliseconds and high sample rates of tens of Mega-samples per second. A demonstration of a weak grid is presented showing effects of linear and non-linear loads on the supply source and power quality.