用电荷模拟技术计算交流电晕导线的离子流场

M. Abdel-Salam, D. Shamloul
{"title":"用电荷模拟技术计算交流电晕导线的离子流场","authors":"M. Abdel-Salam, D. Shamloul","doi":"10.1109/IAS.1988.25284","DOIUrl":null,"url":null,"abstract":"A method is developed to compute the ion flow from AC corona-discharging wire above the ground plane, without resort to simplifying assumptions. In this method, ions are emitted from the wire into the space around it when the surface gradient of the wire exceeds the onset value. The space charges are simulated by discrete line charges, and the C-S technique is used to compute the charge emission from the wire during corona periods over both the positive and negative half cycles. The simulation line charges are displaced away from and back to the wire by prevailing AC field with a subsequent recombination between the outgoing and returning line charges of opposite polarities. Among the parameters computed are: (1) the corona current components and their time variations during the positive and negative half-cycles; (2) the corona charge-voltage characteristics for different applied voltages; and (3) the corona onset and the ionization onset voltages as well as the corona ending voltage over the succeeding positive and negative half cycles.<<ETX>>","PeriodicalId":274766,"journal":{"name":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Computation of ion-flow fields of AC coronating wires by charge simulation technique\",\"authors\":\"M. Abdel-Salam, D. Shamloul\",\"doi\":\"10.1109/IAS.1988.25284\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method is developed to compute the ion flow from AC corona-discharging wire above the ground plane, without resort to simplifying assumptions. In this method, ions are emitted from the wire into the space around it when the surface gradient of the wire exceeds the onset value. The space charges are simulated by discrete line charges, and the C-S technique is used to compute the charge emission from the wire during corona periods over both the positive and negative half cycles. The simulation line charges are displaced away from and back to the wire by prevailing AC field with a subsequent recombination between the outgoing and returning line charges of opposite polarities. Among the parameters computed are: (1) the corona current components and their time variations during the positive and negative half-cycles; (2) the corona charge-voltage characteristics for different applied voltages; and (3) the corona onset and the ionization onset voltages as well as the corona ending voltage over the succeeding positive and negative half cycles.<<ETX>>\",\"PeriodicalId\":274766,\"journal\":{\"name\":\"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.1988.25284\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1988.25284","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文提出了一种计算交流电晕放电导线在地平面以上离子流的方法,而无需简化假设。在这种方法中,当导线的表面梯度超过起始值时,离子从导线发射到导线周围的空间中。空间电荷用离散线电荷模拟,利用C-S技术计算了正负半周电晕周期内导线的电荷发射。模拟线路电荷被主流交流电场从电线上移开或移回,随后极性相反的出线电荷和返回线电荷重新组合。计算的参数包括:(1)正负半周电晕电流分量及其时间变化;(2)不同外加电压下的电晕电荷电压特性;(3)电晕起始电压和电离起始电压以及电晕结束电压在随后的正半周期和负半周期。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Computation of ion-flow fields of AC coronating wires by charge simulation technique
A method is developed to compute the ion flow from AC corona-discharging wire above the ground plane, without resort to simplifying assumptions. In this method, ions are emitted from the wire into the space around it when the surface gradient of the wire exceeds the onset value. The space charges are simulated by discrete line charges, and the C-S technique is used to compute the charge emission from the wire during corona periods over both the positive and negative half cycles. The simulation line charges are displaced away from and back to the wire by prevailing AC field with a subsequent recombination between the outgoing and returning line charges of opposite polarities. Among the parameters computed are: (1) the corona current components and their time variations during the positive and negative half-cycles; (2) the corona charge-voltage characteristics for different applied voltages; and (3) the corona onset and the ionization onset voltages as well as the corona ending voltage over the succeeding positive and negative half cycles.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信